4
5
EN
EN
IEVO-M
micro™ Fingerprint Reader
5] INSTALLATION GUIDANCE
The micro™ reader is suitable for internal use only.
The micro reader can be either flush or surface mounted. Ensure you use the
correct fixings and plugs for the type of wall for which you are fixing the reader.
Incorrect usage can result in the Micro reader being unsecure.
The micro reader should only be mounted vertically. It is not recommended to
mount any ievo reader horizontally as this can affect performance and usability.
We recommend that you install the Micro reader following DDA Guidelines,
installing the reader at a height of between 1m and 1.2m. This is the optimum
height for finger placement.
The ievo Control Board must be installed on the protected side of the door or
turnstile. The control board is not IP rated, but can be installed inside most IP
rated enclosures.
POWER
A single ievo control board with two micro readers connected will pull 1.6Amps
when operating at full capacity. We recommend that you use a Surge Protected,
12 – 24V, AC (Alternating Current) or DC (Direct Current), 2Amp power supply
unit (PSU) to power each ievo Control Board. We also recommend fitting a backup
battery.
It’s important you correctly calculate the amperage rating if using a shared PSU.
If using separate PSU’s for separate equipment, ensure they share a common
ground connection.
ievo equipment must be used with an EN 60950-1 or an equivalent IEC standard
complaint PSU. This is to establish adequate safety testing of the PSU to ensure
that there is enough isolation provided from the mains supply.
Please ensure that the cable used between the Power Input on the ievo Control
Board and your chosen Power Supply Unit is adequate for the current, amperage
and environment.
If you are using an ievo Control Board with a Power Over Ethernet (PoE) module,
you will require a POE+ (802.3at) rated injector or switch to supply power and
network connectivity.
Please follow ESD Safety Procedures to prevent any damage to electronic components.