2- FACTORY SETTINGS

2- RECEIVER SET-UP

!

A flash of 1 second of L2 indicates that a correct signal has been received 
and that the correct frame in wiegand format has been sent from the 
outputs DATA0 and DATA1.

!

If L2 blinks quickly it means that the combination is not memorized ( a 
different button or a different Facility Code )  

!

A long flash of L2 indicates a transmitter with wrong  Manufacturer key 

The information contained in the frame sent by the transmitter is composed by 
4  main  parameters: 

Manufacturer  Key, 

NUMBER and Button type

.

The receiver accepts 

transmitters with the right Manufacturer Key 

( ERONE ) and, once initialized, sends out in wiegand format the S/N of the 
transmitters having the right Facility-code / Button type  . 
No  wiegand  formatted  signal  is  carried  out  from  the  receiver  unless  a 
initialization procedure is performed.
Follow the procedure below to create the filter in the receiver memory.

FACILITY  CODE,  SERIAL 

only 

4- FACILITY CODE CHECK DISABLING

It is possible to disable the check performed by the receiver on the facility 
code of the received signal. 

At the end of the following procedure, the receiver accepts any 
facility code and maintains the check on the button code.

This new configuration of the receiver is temporary and can be restored by 
carrying on the same procedure.

1) Keep the button P1 pressed down until the led L2 turns on and then 
release it.
2) Within 1 sec. press again P1.
At this point the led L2 start to blink for 5 sec. : the receiver accepts any 
facility code.
Repeat the phases 1 and 2 to cancel the operation and to recover the 
initial state.
L2 first will blink and then will come back to solid light for 5 sec.: the 
facility code checking is restored.
If a power failure occurs after the phase2 the new configuration is 
mantained. 

5- VISUALIZATION

6- MEMORY ERASURE

This procedure allows to erase the memory of the receiver.
1) Keep button P1 pressed down until L2 turns on.
2) Release P1 and then press it again until L2 start to flash 3 times.

At this point the settings stored are cancelled, and the receiver doesn’t 
accept anymore transmitter code, as a new product.

7- WIEGAND SIGNAL FORMAT

The timing of the signals DATA0 and DATA1 are the following:

NRZ

DATA1

DATA0

80 µS

2 mS

IS

-RW4ERUK R

ev

. 3 del 13.06.2017

Before commencing the procedure make sure that the power led L1 is ON.
The  EEPROM  of  the  receiver  is  capable  to  store  up  to  50  different 
combinations: “Facility code - Button type”.
The button type of each transmitter can be A, B, C, D.
Combinations of this type can be, for example: 
001-A, 001-B, 002-B, 003- B, 010-D, where 002 is the Facility code and B is 
the transmitter button and so on. 
Combinations as A+B or C+D are not allowed. 

Transmitter button A programming

1) Keep the button P1 pressed down until the led L2 turns on and 
release it.
2) Press the button A of the transmitter which has to be accepted.
3) The led L2 turns off and then make a short flash.

After this operation, the receiver will accept and send out the Facility code 
and the S/N of all the transmitters with the same Facility code and the same 
button of the one used for the initialization.  
NOTE : in the wiegand signal frame there is no information about the button 
type ( see chapter 8).
See below  to get the signal out using more combinations : buttons B, C or D.

Transmitter button B programming

1) Keep the button P1 pressed down until the led L2 turns on and 
release it.
2) Press the button B of the transmitter which has to be accepted
3) The led L2 turns off and then make a short flash.

Transmitter button C programming

1) Keep the button P1 pressed down until the led L2 turns on and 
release it.
2) Press the button C of the transmitter which has to be accepted
3) The led L2 turns off and then make a short flash.

Notice

Any changes or modifications on ERONE equipment not expressly approved by CDVI 
Wireless Spa could void the user’s authority to operate with the equipment.

Manufactured by CDVI Wireless Spa

Via Piave, 23 - 31020 

San Pietro di Feletto (TV) - Italy

Tel: +39-0438-450860 - Fax: +39-0438-455628

E-Mail: [email protected]

Web: www.erone.com

The guarantee period of all Erone products is 24 months, beginning from the 
manufacturer date. During this period, if the product does not work correctly, due 
to  a  defective  component,  the  product  will  be  repaired  or  substituted  at  the 
discretion of the producer. The guarantee does not cover the plastic container 
integrity. After-sale service is supplied at the producer's factory.

GUARANTEE

8- FRAME ARCHITECTURE

The 26- Bit Wiegand datagram is composed by as follows:

P1

P2

Facility code

Serial number

LEGENDA :

P1 = Parity even calculated over the first 12 bit : First bit coming out 
Facility code = 8 bit
Serial Number = 16 bit
P2 = Parity odd calculated over the last 12 bit: Last bit coming out

Transmitter button D programming

1)  Keep  the  button  P1  pressed  down  until  the  led  L2  turns  on  and 
release it.
2) Press the button D of the transmitter which has to be accepted.
3) The led L2 turns off and then make a short flash.

Any operation not allowed ( memorization with full memory, memorization of  
codes already stored ) causes a double quick flash of led L2.
A  transmitter  with  wrong  manufacturer  key  is  signalled  during  the 
memorization with a long flash of L2