1A - Description
The receiver ERONE type SELWR433 is a superheterodyne receiver operating
at the frequency 433,92 Mhz in AM/ASK. It is composed by a main board in
which there are the power supply output connectors and by a RF card. The
two outputs have an open drain configuration with output signal in “Wiegand
26 bit format”. The appliance is housed in an indoor enclosure. Hereby,
CDVI Wireless Spa, declares that the radio equipment type SELWR433 is in
compliance with directive 2014/53/EU. The full text of the EU declaration of
conformity is available at the following internet address: www.erone.com.
1B - Usable transmitters
!
ERONE Series MINI Type. SETR2643AM2: 2 keys transmitter
!
ERONE Series 024A Type S2TR2641E2-E4
!
ERONE Series 054A Type S5TR2641E2-E4
!
ERONE Series 074A Type S7TR2641E4
1C - Technical specifications
Receiver type:
Superheterodyne.
Demodulation:
AM/ASK.
Operating frequency:
433,92 MHz.
Local oscillator frequency:
6,6128 MHz.
Intermediate frequency:
10,7 MHz.
Sensitivity:
-115 dBm.
Input impedance:
50 Ohm.
Power supply :
12 ÷ 24 V ac/dc.
Current consumption:
24 mA
Output s number:
2
Output type:
Wiegand.
Max output current:
250 mA
Operating temperature:
-20 ÷ + 70 °C.
Overall dimensions:
105 x 45 x 28 mm.
Weight:
65 gr.
IP Protection Grade:
IP2X
INST
ALLA
TION
MANU
AL
433 MHz WIEGAND RECEIVER
1- RECEIVER INTRODUCTION
1D - Receiver Layout
P1 : Programming button
L2 : Red led ( programming )
L1 : Green led ( power supply )
1E - Terminal board connections
1 - Not used;
2 - Output DATA1 ( Open collector );
3 - Output DATA0 ( Open collector );
4 - Power Supply ( 12 ÷ 24 Vac/dc );
5 - Power GND;
6 - Not used;
7 - Antenna Shield;
8 - Antenna Core;
1- RECEIVER INTRODUCTION
2- FACTORY SETTINGS
3- RECEIVER SET-UP
4- DEFAULT RECEIVER CONFIGURATION
5- FACILITY CODE CHECK DISABLING
6- MEMORY ERASURE
1A
Description
1B
Usable transmitters
1C
Technical specifications
1D
Receiver layout
1E
Terminal board connections
Thank you for choosing an ERONE product. You are recommended
to read this manual carefully before installing the product.
7- WIEGAND SIGNAL FORMAT
CONTENTS
The receiver allocation is very important for the best operation of the
system.
Place the receiver far from interference sources such as big magnetic
fields or radio emissions.
The installation and the positioning of the antenna is very important
as well. Before to install the antenna it is advisable to make some
tests on the site.
Use shielded cable type RG58 ( impedance 50 Ohm ) for the
antenna connection.
IMPORTANT
8
7
6
5
4
3
2
1
GND
12-24V
L2
P1
DA
TA1
DA
TA0
L1
S E L W R 4 3 3
T H E S M A R T L I V I N G
8- FRAME ARCHITECTURE
45
105
28
Green
Red