P2 : RESTORE
P1 : RESET
Green LED
ERMU
Advanced Multiuser Receiver
WEB SERVER MANUAL
EN
27
www.erone.com
www.cdvigroup.com
27
Manufactured by :
CDVI WIRELESS S.p.A. - CDVI Group
Via Piave, 23
31020 S. Pietro di Feletto (TV) - ITALY
Tel. +39.0438.450.860 Fax +39.0438.455628
E-mail: [email protected]
Web: www.erone.com
MODULE CRASH RECOVERY
If for any reason the module MD-WIFI stops working, it is possible to restart it.
Follow the procedure below.
1) press and keep pressed the button P2
2) keeping P2 pressed, Press P1 for 1 sec.
3) keep P2 still pressed until the GREEN LED makes a Flash
At the end of the procedure, the data-base of the users remains unchanged but all the changes carried out on
the working parameters have been restored to factory values.
That means that the Module will restart operating as WIFI AP, with the factory coordinates for accessing
(
ermu-XX:XX:XX
) where XX:XX:XX are the characters of the MAC Address and password :
adminiadmin
.
After a restart, the module can also be seen inside a LAN both at the static address previously assigned by the
router or at the address
192.168.1.1
Another system to access the module, is to make a direct connection with a PC ( isolated from other networks)
using a LAN cable.
Once connected, the PC can see the module at the address :
10.253.252.251.