CDVI DGPROX Manual Download Page 9

9

Template

 

DGLI and DGLP Auxiliary reader

]

FCC statement:
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
      from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for  help.

Caution:
Changes or modifications not expressly approved by C.D.V.I. could void the user's
authority to operate the equipment.

Block terminal

 43x15 mm

60
mm

96
mm

75   mm

25  mm

6  mm

Summary of Contents for DGPROX

Page 1: ...Request to exit PB1 E Alarm Input M Common PB1 E and 4 O Relay 1 contact C Common T Relay 2 N O contact I1 Anti tamper switch V1 Varistor ST1 ST2 Jumper for reset Jumper for relay 1 RL1 Door relay RL...

Page 2: ...Alarm Off Audible signals 1 beep long Validation of data in programming mode master code proximity badge or time delay Or access code validated 2 beeps short Accessing the programming mode or exiting...

Page 3: ...up to 99 for 99 seconds 00 sets a latched output toggle on toggle off The LED goes out for 1 second and an audible beep indicates the time delay has been accepted Alarm Relay Enter 2 then the time in...

Page 4: ...ons Mode 00 Present the badge in front of the DGPROX one audible beep will sound to confirm that the badge is valid then enter the PIN code Mode 01 Present the badge in front of the DGPROX reader or o...

Page 5: ...Time delays Function n Values Programmed values Keypad key in delay 0 10 10 sec 99 99 sec Door relay 1 01 1 sec 99 99 sec opened door before alarm 2 00 without alarm 01 10 sec 99 990 sec Master code 3...

Page 6: ...2 V 1 4 5 12 Distance minimum 60cm maximum 50 m Auxiliary reader terminal connections Input voltage 12V or 230V 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED...

Page 7: ...7 Template DGPROX 31 mm 26 mm 110 mm 125 mm 137 mm 29 mm 22 mm 45 mm 68 mm 86 mm Wiring Access Area 30 x 40 mm...

Page 8: ...8...

Page 9: ...erence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the us...