BP1
PB1
BP2
PB2
P1
P2
230 V AC
Alimentation
Input voltage
12V / 24V AC
12V / 48V DC
12 VDC
ADC335
Alimentation
préconisée
Recommended
Power Suply
@:,5,1*',$*5$0*$/(25(/$<2873876
EN
GALEO 4.0 Bluetooth
:HDWKHUSURRI,OOXPLQDWHG.H\SDGZLWKUHPRWHHOHFWURQLFV
INSTALLATION MANUAL
R
e
m
o
te
e
le
ctr
on
ics
P2
jumper allows
to the user to modify
its own Pin code.
To enable this feature put
the jumper on.
P1
jumper resets the
keypad to factory default
values. Remove the power
from the keypad then put
the jumper.
PB1
request-to-exit input activates relay 1.
PB2
request-to-exit input activates relay 2.
Latch or toggled output.
H
input can be used with a timer to enable
free access by pressing on any digit key on
the keypad.
When the contact is open
then the request-to-enter is disabled.
When the contact is closed then press any
key on the keypad to enter.
Outputs
Wiring table
INPUT
V
Input voltage 12V to 24VAC or 12V to 48VDC
V
Input voltage 12V to 24VAC or 12V to 48VDC
DOOR 1
NC
N/C contact relay 1
C
Common relay 1
NO
N/O contact relay 1
DOOR 2
NC
N/C contact relay 2
C
Common relay 2
NO
N/O contact relay 2
DOOR 3
NC
N/C contact relay 3
C
Common relay 3
NO
N/O contact relay 3
Push
button
PB1
Request-to-exit input relay 1
M
Common of inputs
PB2
Request-to-exit input relay 2
Clock
PX
Not used
H
Not used
H
Timer Contact
Keypad
TMGALEO
+
White wire from keypad
-
Brown wire from keypad
E
Green or Blue wire (illumination)
13