CDVI 500-LADJ Quick Start Manual Download Page 3

EN

EN

500-LADJ

Electromagnetic Lock Bracket

3

3.  Mount the magnet to the flat sliding plate in the same way you would for a stand   

      ard “L” bracket (see diagram below) and secure through the 2 or 4 pre-drilled holes,  

     depending on the magnet you are using.

4.  Ensure the hole where the wire comes out of the magnet corresponds with the one 

     on the flat plate and that the magnet faces outwards on the edge of the slide plate

     (see drawing below).

This can all be pre prepared before attending site or in bulk on site before taking to 

each door location in order to save time.

STEP II

Fit the armature to the door and secure the main body to the transom in the same way 

you would with an “L” bracket taking care to ensure that the sliding plate can travel 

freely under the transom.

Depending on the type of door frame 

the mag lock can be fitted at the 

front or the back of the plate which is 

achieved by simply turning the plate 

around