CDN ProAccurate SD1110X Manual Download Page 2

C. Backlit Display 

Press and hold the UNIT button for 3 seconds  
to turn the backlit display on and off. 

D. Unit Selection 

Press the UNIT button to select the desired unit. 
The display cycles through 

g

lb:oz

lb:/oz

lb

oz

and 

/oz

.

E. Tare 

The tare function resets the scale display to zero 
in order to measure only the weight of an item. It is 
frequently used to subtract the weight of containers.
1. When the scale is on, place a container on 

the platform. 

2. Press the TARE button to reset the display  

to zero.

3. Place the item into the container or directly on 

the scale platform. The weight of only the last 
item added will appear on the display.

4. Continue to repeat steps 

2.

 and 

3.

 to measure 

the respective weights of additional items. 

5. To clear the tare, remove all items from the 

platform and press the TARE button. The display 
is reset to zero.

F.  Low/High Limit Alerts 

The scale may be set to alert you when an item’s 
weight is under or over a set limit.
1. Press and hold the TARE button for 3 seconds. 

The scale beeps as 

LOW

 and the zero weight 

appears on the display.

2. Place a weight equal to the low weight limit on 

the platform and press the SET button. A beep 
indicates that the low limit is set.

3. 

HIGH

 appears on the display. Add weight to the 

platform until the weight is equal to desired 
high weight limit. Press the SET button. A beep 
indicates that the high limit is set. 

4. Remove all items from the platform.
5. An alert will now sound if an item placed on 

platform is over or under the set limits. 

LOW

 

or 

HIGH

 appears on the left side of the display 

when these conditions exist.

6. To clear the Low/High limits, press both SET and 

TARE buttons simultaneously.

G. Field Calibration

1. When scale is off, press and hold POWER button 

( ) until the scale turns on. When all segments 
are on, release the POWER button ( )  
and press the UNIT button 3 times within one 
second. The display shows 

11111

, then 

55555

and then the version number and checksum 
appear before resetting to zero.

2. Making sure there is no load on the platform, 

press the SET button to save the zero value.

3. Put a 5 kg calibration weight on the platform.

4. Press the SET button again to start the  

auto-calibration. The scale shows 

5000 g

  

and then 

CAL

 before automatically turning off. 

The calibration is complete.

H. Battery Status 

 

Low Battery:

 Battery status is low and needs  

 

to be charged. See 

Charging the Battery

 on  

 

page 1.

I.  Error Messages 

oL

 indicates an overload when the item being 

measured exceeds the capacity of the scale. 
Immediately remove the overweight item to avoid 
causing permanent damage to your scale.

J.  Programmable Modes 

The scale has been pre-configured at the factory 
and should not require configuration for use in most 
applications. In the event that the factory settings 
do not meet the requirements of your application, 
the following describes the steps  
to configure the scale.

1. Units 

The scale has been pre-configured at the factory 
for six units of measure. In the event that these 
do not meet the requirements of your application, 
the following describes the steps  
to limit the number of unit choices available. The 
sequence of units is 

lb:oz

lb:/oz

lb

oz

,  

/oz

 and 

g

.

a. Press the POWER button ( ) to turn on.
b. Press and hold the SET button for 3 seconds. 

When 

SEt

 appears on the display, release the 

SET button to enter the configuration mode. 

UNIT

 appears on the display.

c. With 

UNIT

 appearing on the display, press the 

SET button to select 

lb/OZ

 (pounds/ounce) 

units (11 lb @ 0.1 oz). Both the unit and its 
status appear on the display.

d. Press the UNIT button to toggle between  

ON

 (enabled) and 

OFF

 (disabled).

e. Press the SET button to confirm the status 

and to select the next unit in the sequence. 

f.  Repeat steps 

d.

 and 

e.

 for each respective 

unit. Upon confirming the status for 

g

,  

UNIT

 appears on the display.

g. Press the UNIT button three times.  

END

 appears on the display. 

h. Press the SET button to save the settings and 

return to weighing mode.

2. Auto Off 

The scale has been pre-configured at the factory 
to automatically turn off after 120 seconds  
(2 minutes) of inactivity. In the event that your 
application requires longer shut-off times or none 
at all, the following describes the steps  
to configure this feature.

Summary of Contents for ProAccurate SD1110X

Page 1: ... the adapter plug into the jack in the rear of the scale 2 To turn the scale on press the POWER button as described in Section A On Off The scale will remain on until turned off Note When the power adapter is plugged in the auto off feature is disabled Charging the Battery The LOW BATTERY icon and bAtt appear on the display when battery status is low and needs to be charged The LOW BATTERY icon fl...

Page 2: ...s no load on the platform press the SET button to save the zero value 3 Put a 5 kg calibration weight on the platform 4 Press the SET button again to start the auto calibration The scale shows 5000 g and then CAL before automatically turning off The calibration is complete H Battery Status Low Battery Battery status is low and needs to be charged See Charging the Battery on page 1 I Error Messages...

Page 3: ...mpensation OFF appears on the display 7 Press the SET button to confirm the selection GrAu appears on the display 8 Press the UNIT button END appears on the display 9 Press the SET button to save the settings and return to weighing mode b Gravity Compensation Value Editing Contact CDN for the value to enter for your location Note Gravity compensation must be disabled for this value to take effect ...

Page 4: ...5 6 D cm Weight 77 6 oz 2199 9 g Accessories AC Adapter AD AC1110 Removable stainless steel platform AD PF1110 5 kg calibration weight WT05 01 2018 Component Design Northwest Inc Made in China CD9999372en 1 18 L DESIGN 614 525 1472 The information in this document has been reviewed and is believed to be accurate However neither the manufacturer nor its affiliates assume any responsibility for inac...

Reviews: