OWNER’S
MANUAL
CDL ROTOR
FLOWMETERS
Version 1.0
10/15/2020
© Tous droits réservés – CDL Maple Sugaring Equipment Inc.
Models : 210100 | 210150 | 210200 | 210300
Page 1: ...OWNER S MANUAL CDL ROTOR FLOWMETERS Version 1 0 10 15 2020 Tous droits réservés CDL Maple Sugaring Equipment Inc Models 210100 210150 210200 210300 ...
Page 2: ...e Sugaring Equipment inc 2 TABLE OF CONTENTS INTRODUCTION 3 PRODUCT FEATURES 4 RESETTING TO ZERO 5 INSTALLATION 6 INSTALLATION DIAGRAM 7 SUMMARY BY MODEL 8 CDL MONITORING INTERFACE 9 MAINTENANCE 11 WARRANTY 12 ...
Page 3: ...ad these instructions carefully before installing in order to ensure your flowmeter is as accurate as possible In the Installation Diagram section you will find examples of proper and improper installation The flowmeters come pre programmed from the company You do not need to adjust the settings By default the display will be in gallons However you will be able to see it in litres on your CDL moni...
Page 4: ... temperature 60 degrees Celsius or 140 degrees Fahrenheit Protection IP66 1 model 210100 Minimum flow rate 2 5 GPM Maximum flow rate 79 GPM 1 model 210150 Minimum flow rate 6 5 GPM Maximum flow rate 225 GPM 2 model 210200 Minimum flow rate 10 5 GPM Maximum flow rate 357 GPM 3 model 210300 Minimum flow rate 24 GPM Maximum flow rate 739 GPM ...
Page 5: ...ugaring Equipment inc 5 RESETTING TO ZERO Displays accumulated gallons Display flow rate in gallons per minute gpm Important To reset the accumulated gallons to zero press and hold these two buttons for 3 seconds ...
Page 6: ...sulting the installation diagram for more details 1 As a basic principle the tube should always be full so that the flowmeter can get a proper reading 2 Reduce turbulence inside the tube as much as possible to ensure accuracy 3 The Mesh communication module can be screwed into the desired location ...
Page 7: ...NSTALLATION DIAGRAM correct incorrect 10x ID 10x ID 5x ID Incorrect if flow rate controlled by a valve 10x ID 5x ID incorrect 10x ID 5x ID incorrect correct Note The ID is inner diameter Correct if flow rate controlled by a valve correct ...
Page 8: ...o elbows of 15 minimum before the flowmeter s inlet 5x x ID Straight line no elbows of 7 minimum before the flowmeter s inlet 2 Model 210200 10x ID Straight line no elbows of 20 minimum before the flowmeter s inlet 5x x ID Straight line no elbows of 10 minimum before the flowmeter s inlet 3 Model 210300 10x ID Straight line no elbows of 30 minimum before the flowmeter s inlet 5x x ID Straight line...
Page 9: ...9 CDL MONITORING INTERFACE Step 1 Find your flowmeter which is connected to the CDL monitoring system in the interface In the Device tab click on Flowmeters You will be redirected to this page where you will see your flowmeter s number ...
Page 10: ...CDL Maple Sugaring Equipment inc 10 Step 2 Rename your flowmeter as desired To view a flowmeter s data simply click on its tab Click here Enter the desired name here and save Click here ...
Page 11: ...nsweetened plain water at the end of the season If the flow rate displays zero while running make sure that the small inner rotor is not obstructed Make sure it rotates freely without friction Use warm water to thoroughly rinse and clean it as needed to keep it turning freely Turn off the power supply if the device is not going to be used for a long period of time Note The flowmeter will remember ...
Page 12: ... 4 Failure to follow CDL s maintenance procedure 5 Production losses caused by problems with the flowmeter 6 Loss of income caused by the quality of the syrup 7 Service calls that do not involve malfunctions manufacturing or material defects or products that were not used according to the instructions provided 8 Service calls to check installation or receive instruction on using the flowmeter 9 Se...
Page 13: ...ations on warranties In this case these restrictions or exemptions may not be applicable This written warranty gives you specific legal rights Depending on the state or province you may have other rights If you need to call the repair service Keep your receipt delivery note or other valid proof of payment to establish the warranty period in case you need to call for repairs If a repair is made it ...