averages. 

Please note that the meter has limited sensitivity to very short pulses 

of air flow, and filtering or averaging the output does not alter this. 

Alarms 

If user-specified thresholds for minimum or average are exceeded, indicating 

excessive air usage, the corresponding LEDs will blink. These blinks are short, 

with the LED lit one eighth of the time. If the same LED is lit to indicate the 

current display mode, it will blink off for one eighth of the time. 

Units of Measure 

Five options of units are available. Units should be set in accordance with local 

custom and should match the markings on the cover of the meter. 

Programming 

With the meter displaying rate, press and hold the button. The minimum LED will 
light immediately; when the average LED lights, release the button. The display 
will now show two letters on the left and two digits, with or without a decimal 
point, on the right. The letters indicate which parameter is being programmed; 
the digits indicate the current value of the parameter. When a three-digit 
parameter is displayed, one of the letters will be overwritten. To advance the 
parameter, press and release the button; to advance the parameter rapidly, press 
and hold the button. To advance to the next parameter, just wait. Time is 
displayed in hours and tenths of hours. 

symbol 

meaning 

description 

range 

LL 

Low Limit 

Threshold for minimum 
flow alarm 

0.1  cfm to 
99 cfm 

LP 

Low Period 

Period over which 
minimum flow is 
calculated (hours) 

0.1  hr to 
24 hr 

AL 

Average Limit 

Threshold for average 
flow alarm 

0.1  cfm to 
99 cfm 

AP 

Average 
Period 

Period over which 
average flow is 
calculated (hours) 

0.1  hr to 
24 hr 

FF 

Filter Factor 

Degree of filtering 

– no filtering 

– maximum filtering 

dd 

default 
display 

  0 

– rate 

  1 

– minimum 

– average 

– total 

du 

display units 

        Rate 
  0 

– cfm 

  1 

– Nm3/hr at 0 deg C 

  2 

– Nm3/hr at 20 deg C 

  3 

– Nm3/min at 0 deg C 

  4 

– Nm3/min at 20 deg C 

    Total 
1000 cuft 
m3 at 0 deg C 
m3 at 20 deg C 
m3 at 0 deg C 
m3 at 20 deg C 

 
 

Summary of Contents for CDI 25 Series

Page 1: ...ty times the diameter at a minimum Five diameters of straight downstream pipe is sufficient unless the meter is immediately upstream of something that would restrict the flow such as a valve Select a location that meets these requirements and also provides good visibility Preparing the Holes When the holes are drilled metal shavings will enter the pipe Make sure that filters or other provisions ar...

Page 2: ...er is in the rate mode Minimum and Average Modes The minimum and average functions look back over periods of time specified by the user Each is based on 360 samples taken over the specified period of time Minima and averages are calculated and stored for groups of 36 samples so the displayed results are updated at an interval of one tenth of the period specified by the user Thus if the average is ...

Page 3: ...ithout a decimal point on the right The letters indicate which parameter is being programmed the digits indicate the current value of the parameter When a three digit parameter is displayed one of the letters will be overwritten To advance the parameter press and release the button to advance the parameter rapidly press and hold the button To advance to the next parameter just wait Time is display...

Page 4: ...er shall be free from defects in materials and workmanship when given normal proper and intended usage for three years from the date of purchase During the warranty period CDI will repair or replace at its option any defective product at no cost to the buyer The foregoing warranty is in lieu of any other warranty express or implied written or oral including any warranty of merchantability or fitne...

Reviews: