GENERAL
Makes sure that the unit will keep working at a higher ambient temperature than the standard value – see technical
specifications – and discharges the surplus heat to the swimming pool water.
HYDRAULIC CONNECTION
If the unit is fitted with a swimming pool condenser, this must be connected via a bypass or a separate pump to the
return circuit line from the filter installation.
CONNECTION OF THE POOL CONDENSER HAS TO BE EXECUTED
B E F O R E
CONNECTION TO THE WATER TREATMENT INSTALLATION (CHEMICAL OR ELECTROLYTIC).
(
1) Filter installation
(2) Throttling valve
(3) Shut-off cock
(C) Swimming pool condenser
The
IN
and
OUT
are marked
COAX IN
and
COAX OUT
.
The throttling valve must be turned such that the temperature difference between
IN
and
OUT
is
±
8°C.
We recommend using a heat- and pressure-resistant line for the first 3 m (eg: PEX).
Type of unit
65
100-102M
140-142M
Capacity
kW
3,62
4,66
6,63
Air flow
L/h
400
550
660
Pressure loss
kPa
8,5
15
21
CONTROL
ELECTRICAL CONNECTIONS/ SEE DIAGRAM
Via the maximum built-in thermostat
: at excess temperature (> 32°C) the unit control can be ordered to emit
extra heat. The extra heat is diverted into the swimming pool water and the temperature of the expelled air is equal
to that of the air drawn in.