16
Error Message
Probable Error
The process to be done
The green light flashes
twice every 5 seconds with
the beeper sounding.
The door is not shut
properly during steam
cooking.
Shut the door.
The green light flashes
three times every 5
seconds with the beeper
sounding.
Water reservoir not
correctly seated or
Water reservoir empty
or
The “O” ring is missing
from the reservoir exit
tube.
Make sure the water reservoir is correctly
seated and has adequate water in it.
Ensure the “O” ring on the exit tube is present
and has not perished.
If the error persists, isolate the appliance and
contact CDA Customer Care.
The green light flashes
once every 5 seconds with
the beeper sounding.
Boiler pump error.
Switch off the appliance and allow to cool
before switching on again.
If the error persists, isolate the appliance and
contact CDA Customer Care.
The green light flashes
once every 5 seconds
and continous fast beeper
sounding.
Probe or potentiometer
fault.
Isolate the appliance and contact CDA
Customer Care.
Both the green and
red lights illuminated
continuously and the
beeper sounding 5
second blasts at 10 second
intervals.
Both the “Grill” knob
and “Steam oven” knob
are turned on.
Turn one of the knobs to the “0” position.
The green light flashing
rapidly and the beeper
sounding continuously.
The appliance has
experienced a power
cut.
Turn off the cooking function that is in use then
turn it on again.
Error Codes
Your machine is equipped with a diagnostic system which
monitors progress and will gives visible signals if it detects unusual
circumstances.