Page 1: ...mer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu HVG620 HVG720 Gas Hob Manual for Installation Use and Mainten...

Page 2: ...have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenan...

Page 3: ...saving both energy and resources As a reminder of the need to dispose of household appliances separately the product is marked with a crossed out wheeled dustbin Please note Gas hobs become hot and r...

Page 4: ...ight Semi Rapid burner 1 75kW 4 Auxiliary burner 1 0kW Control panel 5 Rapid burner control knob 6 Left Semi Rapid burner control knob 7 Right Semi Rapid burner control knob 8 Auxiliary burner control...

Page 5: ...panel Turning the control knob to the positions shown below achieves the following Closed OFF position Maximum position Provides fast boiling function Minimum position Provides simmer function The hob...

Page 6: ...ess a clicking sound will be heard Hold down the control knob for a few seconds after ignition to allow the safety device to detect that the burner is lit 2 Once the burner is lit adjust the burner po...

Page 7: ...accommodate most shapes and sizes of pan For best results only use pans with flat bottoms and choose an appropriate burner depending on the size of the pan The most efficient use of the hob is shown...

Page 8: ...enamelled parts of hobs are not suitable for cleaning in dishwashers these should be washed by hand IMPORTANT Steam cleaners must not be used when cleaning this appliance Ensure that all parts are cor...

Page 9: ...3 8 2 6 277 272 Total rated gas input 7 5kW HVG620 11 3kW HVG720 Mains electrical voltage 230 240Vac 50Hz Total rated electrical consumption 1 1W If your Hob is not working 1 Check that the mains supp...

Page 10: ...with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the termin...

Page 11: ...A Group Ltd is not legally able to provide any assistance in the installation of gas appliances except to Gas Safe registered installers Any Gas Safe registered fitter requiring help must provide thei...

Page 12: ...han 5m3 The following table details the requirements based on the kitchen volume L x W x H in m3 The above requirements also allow use of a gas oven and grill but if there are any other fuel burning a...

Page 13: ...rom the gas and electrical supplies 2 Remove burner components and pan supports 3 Remove the injectors and replace with the corresponding injector as shown in the table below Setting up minimum flow r...

Page 14: ...operation at a nominal inlet pressure of 37mbar or butane operation at a nominal inlet pressure of 28 30mbar to natural gas at 20mbar This conversion must only be carried out by a competent person i e...

Page 15: ...fitting a cooker hood above the hob If a cooker hood is to be installed above the hob the height of the hood above the hob must be at least 700mm 750mm is recommended Fig 6 If the instructions suppli...

Page 16: ...to be built in below the hob it is recommended that an isolation shelf should be fitted to protect the user from high temperatures If the hob is to be installed above a working drawer then a partition...

Page 17: ...The cut out Fig 6 shows a 61 5mm gap from the wall to the cut out edge The distance for the hob when fitted to the back wall is 50mm 2 Position the hob seal as shown in the diagram below Fig 8 ensurin...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ct our Customer Care Department or for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W...