28
3.7kW-7.4kW modes
When configured in any mode other the 2.8kW, the hob should be
installed into a dedicated cooker outlet and protected by the size of
fuse shown in the table above.
This appliance is intended to be connected to fixed wiring by a double
pole switch, having a contact separation of at least 3mm in all poles.
The switch must be positioned no further than 2m from the appliance.
Please note:
The mains cable must only be replaced by a qualified electrician or
service engineer and be of a cross sectional area appropriate for the
power configuration mode of the hob, as shown in the table above.
The marking of the current rating of the fuse or circuit breaker
protecting this appliance should be marked on the socket outlet.
Assembly and electrical connection should be carried out by
specialised personnel.
When installing this product we recommend you seek the help of
another individual.
Ensure that the brass links are securely fitted. Failure to do so will
prevent the hob from operating correctly.
Any service call arising from incorrect installation may result in a
charge.