Mains Electricity Connection

Warning! this appliance must be earthed

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who 
will comply with the I.E.E. and local regulations.

This appliance is intended to be connected to fixed wiring and is not suitable for connection to a 13A plug or 
13A supply.

This appliance is intended to be connected to fixed wiring by a double pole switch, having a contact separation of at 
least 3mm in all poles. The switch must be positioned no further than 2m from the appliance.

This appliance is supplied with a 3 core mains cable; the wires are in accordance with the following code:

Green & Yellow = Earth

Blue = Neutral

Brown = Live

Please note:

•   The mains cable must only be replaced by a qualified electrician or service engineer and must be of equivalent or  
 

better rating (i.e. 2.5mm

2

, HO5V2V2-F).

•  

This appliance is intended to be connected to the mains supply with a cable of cross section area 2.5 mm2. A  

 

 

larger cable will not fit the terminal connections.

•  

The marking of the current rating of the fuse or circuit breaker protecting this appliance should be marked on the  

 

 

socket outlet.

•  

Assembly and electrical connection should be carried out by specialised personnel.

•  

When installing this product we recommend you seek the help of another individual.

 

Fig.7

Black - grey

Green / yellow

Blue

Brown

N

L

Green / yellow

Blue

Brown

N

L

Use a 32A circuit breaker or fuse

or

Summary of Contents for HCN610

Page 1: ...partment The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style HCN610 Induction Hob Manual for Installation Use...

Page 2: ...T IN ACCORDANCE WITH EC DIRECTIVE 2002 96 EC At the end of its working life the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling...

Page 3: ...physician Important Do not use the hob if the glass surface is cracked or damaged to prevent the risk of electric shock Disconnect it from the power supply Ensure that the power cable of a connected e...

Page 4: ...he table below offers guidance as to what each power level is for Switch position Type of cooking 0 Switched off 1 2 For melting butter chocolate or keeping food warm 2 3 Keeping food hot or to heat s...

Page 5: ...n be used on each zone separately To set the timer First switch on the zone and set the power level Touch the timer key repeatedly until the LED in the timer display is lit for the required zone Then...

Page 6: ...still hot to the touch after cooking An H will flash in the relevant zone display after cooking until the zone is at a safe temperature to touch Please note You should avoid touching the zones when th...

Page 7: ...fficient use of the hob is shown below where the pan and zone are correctly chosen Use pan lids where possible to minimize the energy usage of your appliance It is very important that the pans used on...

Page 8: ...s stews potatoes Use specialist vitroceramic glass cleaner preferably one with silicone for its protective properties Care and Maintenance Always disconnect the appliance from the power supply before...

Page 9: ...b is incorrect Call CDA Customer Care The hob produces an odour during the first cooking sessions New appliance Heat a saucepan full of water on each cooking zone for 30 minutes 9 fast frying steaks O...

Page 10: ...ht pelmets is 400mm unless they are manufactured from a material resistant to fire steel for example Notes Do not position this appliance above a refrigeration unit The heat generated may cause the re...

Page 11: ...e cut out edge The distance from the hob when fitted to the back wall is 50mm If a splashback worktop upstand is to be fitted take this into account when cutting the hole The minimum distance that the...

Page 12: ...he wires are in accordance with the following code Green Yellow Earth Blue Neutral Brown Live Please note The mains cable must only be replaced by a qualified electrician or service engineer and must...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...roup Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu Passionate about style To contact our Customer Care Department or for Service please c...

Reviews: