CDA hc6310 Manual For Installation, Use And Maintenance Download Page 9

9

Fig.3

Use a 32A fuse breaker

link wire

Insert a flat blade 
screwdriver to open 
the terminals

Fitting The Hob

Unpacking the hob:

Take care not to lose or mishandle any parts.

Fitting position of the hob:

This appliance must be installed a minimum of 50mm from any 
back wall and a minimum of 180mm away from any adjacent vertical 
surfaces, e.g. a tall cupboard end panel.  This may be reduced to 
100mm if the adjacent surface is resistant to fire (tiles or steel, for 
example).  These dimensions are shown in Fig.4.

If fitting a cooker hood above the hob:

If a cooker hood is to be installed above the hob, the height of the hood 
above the hob must be at least 600mm (650mm is recommended) (Fig.5). 
If the instructions supplied with the hood dictate that the hood must be 
installed at a height greater than 600mm, then that height is the minimum 
required.

Summary of Contents for hc6310

Page 1: ...tomer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu hc6310 Ceramic Hob Manual for Installation Use and Maintena...

Page 2: ...ppliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel Appliance infor...

Page 3: ...tion centre or to a dealer providing appliance recycling services Disposing of a household appliance separately avoids possible negative consequences for the environment and health It also enables the...

Page 4: ...ch the hob surface Do not switch on the zones without cookware in place Do not lean over the hob when it is in use Follow the cleaning instructions carefully Ensure the base of the saucepan is clean a...

Page 5: ...hot after the power is switched off the residual heat indicator will be lit Once the zone has cooled down to a safe temperature the residual heat indicator will switch off Regulating the temperature T...

Page 6: ...sen Use pan lids where possible to minimize the energy usage of your appliance Turn off each zone a few minutes before the end of cooking time The residual heat in the zones will continue to cook the...

Page 7: ...kW If your Hob is not working 1 Check that the control knobs are switched on 2 Check that the mains supply has not been switched off 3 Check that the fuse in the consumer unit has not blown Types of...

Page 8: ...g by a double pole switch having a contact separation of at least 3mm in all poles The switch must be positioned no further than 2m from the appliance Please note This appliance is intended to be conn...

Page 9: ...vertical surfaces e g a tall cupboard end panel This may be reduced to 100mm if the adjacent surface is resistant to fire tiles or steel for example These dimensions are shown in Fig 4 If fitting a c...

Page 10: ...anufactured from a material resistant to fire steel for example Notes Do not position this appliance above a refrigeration unit The heat generated may cause the refrigeration unit to fail This applian...

Page 11: ...out Fig 4 shows a 61 5mm gap from the wall to the cut out edge The distance for the hob when fitted to the back wall is 50mm 2 Position the hob seal as shown in the diagram below Fig 6 ensuring that t...

Page 12: ...ct our Customer Care Department or for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W...

Reviews: