17
Mains Electricity Connection
Warning! this appliance must be earthed.
This appliance must be
connected by a competent
person, using fixed wiring via a
double pole switched fused spur
outlet, protected by a 13A fuse.
We recommend that the
appliance is connected by a
qualified electrician, who is a
member of the N.I.C.E.I.C. and
who will comply with the I.E.T and
local regulations. The wires in
the mains lead are coloured in accordance with the following code:
GREEN AND YELLOW = EARTH BLUE = NEUTRAL BROWN =
LIVE.
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
in your spur box, proceed as follows:
1. The wire which is coloured green and yellow must be connected to
the terminal marked E (Earth) or coloured Green.
2. The wire which is coloured blue must be connected to the terminal
marked N (Neutral) or coloured Black.
$/5",%0/,%37)4#(%$
FUSE SPUR OUTLET
USE A 3 AMP FUSE
USE A 13 AMP FUSE