background image

EVX90SS

Ceiling extractor

Use and maintenance

Summary of Contents for EVX90SS

Page 1: ...EVX90SS Ceiling extractor Use and maintenance...

Page 2: ...xtractor 6 Care and maintenance 7 Installation instructions for standard fitting 15 Installation instructions for mounting the motor externally 15 Ducting 16 Recirculation 17 Mains electrical connecti...

Page 3: ...they have had supervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maint...

Page 4: ...arked with a crossed out wheeled dustbin Please note Under no circumstances should the extractor be connected to any gas ventilation system flue system or hot air ducting system Do not vent the extrac...

Page 5: ...splay will show the letter B Middle speed button Press to activate the middle speed setting the display will show the number 2 Low speed button Press to activate the lowest speed setting the display w...

Page 6: ...water You can also wash the grease filters in a dishwasher ensuring that you place them in an upright position to prevent damage from other items in the dishwasher After rinsing and drying replace th...

Page 7: ...ns for standard fitting Please note All installation measurements given are in millimeters Fig 2 582 882 Make a cutout in the ceiling with the measurements below Fig 3 Dimensions for installation refe...

Page 8: ...t structure Fig 6 Fasten the lower bracket to the upper bracket with the 8 screws supplied We recommend having an 85 100mm gap between the opening in the ceiling and the lowest point of the lower brac...

Page 9: ...g opening make sure to connect your ducting and mains electrical connection before proceeding to the next step Fig 8 Fix the extractor to the bracket with the 6 screws and washers provided Tighten eve...

Page 10: ...he 8 screws fixing the motor housing on the extractor and detach it from the casing Remove the four screws that fix the airguide to the housing and remove it Fig 9 Fig 10 Installation instructions for...

Page 11: ...al 11 Fig 11 Connect the two duct adaptors on both of the panels Fig 12 Fix the airguide to the panel using the four screws removed in Fig 10 note that the air guide is fixed to the opposite side of t...

Page 12: ...e 8 screws supplied note that the airguide is facing the motor Fig 15 Secure the second panel to the rear of the extractor with the 8 screws supplied Locate the extractor in the ceiling opening making...

Page 13: ...Instruction Manual 13 Fig 16 44 80 349 Fig 17 Secure the motor housing to the support structure using appropriate fixings Suggested mounting example...

Page 14: ...14 Instruction Manual Fig 18 Fig 19 Fix the duct adaptor to the motor housing using the 4 screws provided Connect the motor and extractor body using a 150mm diameter ducting hose...

Page 15: ...r DIN102 B1 Wherever possible utilise rigid circular pipe which has a smooth interior rather than the expanding concertina type ducting The maximum length of ducting without performance being affected...

Page 16: ...etres away from the extractor Extraction The extractor is provided with a non return butterfly valve which should be fitted over the vent outlet before the ducting is fitted This prevents cold air bei...

Page 17: ...ed as follows We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C and who will comply with the I E T and local regulations The wires in the mains...

Page 18: ...ed by a suitably qualified person Installation has been carried out in accordance with instructions and current legislations Proof of purchase can be produced The appliance has been used for domestic...

Page 19: ...e fuse replace if blown Wires have disconnected Ensure the power supply is securely connected Output of appliance is low Setting is too low for amount of fumes present Try a higher speed setting Inade...

Page 20: ...ficiency Point QBEP 378 8 m h Measured Pressure at Best Efficiency Point PBEP 423 Pa Maximum airflow QMax 675 m h Measured electric power at Best Efficiency Point WBEP 164 5 W Nominal lighting power W...

Page 21: ...Instruction Manual 21 Notes...

Page 22: ...22 Instruction Manual Notes...

Page 23: ...Instruction Manual 23 Notes...

Page 24: ...The CDA Group Harby Road Langar Nottinghamshire NG13 9HY Sales Department Phone 01949 862010 Email sales cda eu CDA Customer Care Phone 01949 862012 Email customer care cda eu 2020 CDA Group Ltd...