EVX100 Extractor

Manual for Installation, Use and Maintenance

Summary of Contents for EVX100

Page 1: ...stomer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W www cda eu EVX100 Extractor Manual for Installation Use and Maintenan...

Page 2: ...pervision or instructions on how to use the appliance by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by...

Page 3: ...tion centre or to a dealer providing appliance recycling services Disposing of a household appliance separately avoids possible negative consequences for the environment and health It also enables the...

Page 4: ...e extractor in It should be removable for service or maintenance Do not use silicone sealant to secure the hood to the wall You must be able to isolate the extractor from the mains electrical supply a...

Page 5: ...ncrease the speed level touch key C or button 2 on the remote To reduce the speed level touch key B or button 4 on the remote The speed cycles through speed levels and the relevant number indicator wi...

Page 6: ...d hold button 6 on the remote for three seconds The timer The extractor is equipped with a timer that allows the extractor to run for 30 minutes before switching off automatically To activate the time...

Page 7: ...brasive cleaner including Cif will scratch the surface and could erase the control panel markings You can clean your extractor effectively by simply using a dilute solution of water and mild detergent...

Page 8: ...le on the grease filter as shown in fig 3 It will release at the handle side Then lower the grease filter to remove it completely To replace the grease filter repeat the steps in reverse Please note C...

Page 9: ...Then replace the grease filters and cover panels To reset the filter alarms press button E for approximately 3 seconds when the extractor is switched off Care and Maintenance IMPORTANT DO NOT PERFORM...

Page 10: ...use during cooking only The ambient light function can be used for general room illumination Extended use of the extractor light can reduce the life span of the bulb Bulb replacement is not covered b...

Page 11: ...ng an allen key or suitable hex driver 3mm as shown in figure 5 Lift the panel away placing it on a soft surface for safe storage 2 Turn the appliance on its back and disconnect the cable connector fr...

Page 12: ...the ceiling or false ceiling as appropriate with centre point of the hob to start the positioning of the extractor as shown Fixing using the motor structure Two persons required 2 Cut the mounting ape...

Page 13: ...xtractor is to be mounted into a plasterboard ceiling additional supports are required to carry the weight of the extractor The example on the right shows suitable reinforcement batons for use with pl...

Page 14: ...can be adjusted by up to 20mm depending on the installation as shown opposite Slacken the four screws shown and position the fixing mounts to the correct position then re tighten the screws 7 Before...

Page 15: ...t Lift the panel and pull towards the centre of the extractor to expose the connections Carefully disconnect the light connections and place the panels on a soft surface to protect the steel finish Th...

Page 16: ...formation and ensure that the mains electrical supply to the extractor is connected as described in the electrical connection section 5 The extractor is designed to be fitted into a reinforcement fram...

Page 17: ...n the fixing clips should be slackened and then can be accessed by removing the foil covering Push them to fold them into line with the body Take care and get assistance when doing this to prevent the...

Page 18: ...rever possible utilise rigid circular pipe which has a smooth interior rather than the expanding concertina type ducting The maximum length of the ducting without performance being affected is as foll...

Page 19: ...maintenance section of the manual Extraction The extractor is provided with a non return butterfly valve which should be fitted over the vent outlet before the ducting is fitted This prevents cold ai...

Page 20: ...ve panel can be finalised by moving the positions of the cover hinges as shown below Use a suitable allen key or small hex driver 3mm to slacken the cover adjusting screws before sliding the cover int...

Page 21: ...21 Typical installation examples...

Page 22: ...t specified on the rating plate 3 Replace the cover panel and refasten the sliding brackets Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights The light is desig...

Page 23: ...en press button E TC will flash twice to confirm the remote is synchronised TC will flash once to confirm the remote is not synchronised To change the battery The remote control is powered by two stan...

Page 24: ...ions The wires in the mains lead of this appliance are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the a...

Page 25: ...he mains isolation switch should be readily accessible after the appliance has been installed and it is recommended that the isolation switch is located within 2m of the appliance where practical This...

Page 26: ...cooking when most or all of the zones burners are being used simultaneously This is normal and the extractor will work again once the motor has cooled sufficiently If your extractor is not working 1...

Page 27: ...27...

Page 28: ...ct our Customer Care Department or for Service on the details below Customer Care Department The Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E service cda eu W...