background image

In re

-

circulating mode, air is vented 

back into the kitchen through the 

opening in the cooker hood.

This method is advised if you are 

not using your hob intensively.

Re

-

circulated air requires the use 

of charcoal 

lters to remove odours.

Summary of Contents for ECA SERIES

Page 1: ......

Page 2: ...signed constructed and marketed in compliance with safety requirements of EU Directive 2014 35 EU Low voltage and requirements of EU Directive 2014 30 EU EMC IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012 19 EU ...

Page 3: ......

Page 4: ...nding on a number of factors These include type of extraction length of ducting room volume ventilation available and cleanliness of the filters Note For best performance you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking ...

Page 5: ...off button To switch the extractor light on or off Press button A To switch on the extractor or to change the speed at any time when the extractor is running Press the relevant B button for the first second or third speed level as required To switch the extractor off Press button C Fig 1 A B C ...

Page 6: ......

Page 7: ... extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth for example the CDA E Cloth Cleaning the grease filter The grease filter should be kept clean to minimise the risk of fire At least once a month you should remove the grease filter and clean it with hot soapy water You can also wash the grease filter in a dishwasher ensuring tha...

Page 8: ...g mode air is vented back into the kitchen through the opening in the cooker hood This method is advised if you are not using your hob intensively Re circulated air requires the use of charcoal filters to remove odours ...

Page 9: ...2W ...

Page 10: ... with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead for the appliance may not correspond with the coloured markings identifying the terminals connecting to the fused spur proceed as follows The wire which is coloured green and yellow must be connected to the terminal marked E Earth or coloured green The wire which is coloured blue must ...

Page 11: ...114W ...

Page 12: ... be measured from the top of the hotplates or burners Where the extractor is to be installed above a non CDA hob the instructions supplied with the hob may dictate that the height required above the hob is greater than 550mm IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH A GAS HOB THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm The width of any hob must not be greater t...

Page 13: ...correctly installed your product meets all safety requirements laid down for this type of product However special care should be taken around the rear of the appliance as these areas are not designed or intended to be touched and may contain sharp or rough edges that could cause injury Ducting and Ventilation For best performance and lowest noise output we recommend the use of 125mm ducting 100mm ...

Page 14: ......

Page 15: ... Adjust and secure the chimney Fit ducting adaptor Fig 11 Fig 11 Fit the ducting adaptor Fig 12 Mount the lower chimney Fig 13 Mount the chimney Fig 13 Adjust and secure the upper chimney Fig 14 Fig 14 Fix ducting seal joint Fig 12 ...

Page 16: ...16 NOTES ...

Page 17: ...17 NOTES ...

Page 18: ...18 NOTES ...

Page 19: ... f 1 3 1 3 FDEHood 19 0 19 0 EEIHood 68 0 B 68 0 B Measured airflow at Best QBEP 186 5 186 5 m3 h Measured Pressure at Best PBEP 326 326 Pa Maximum airflow QMAX 350 350 m3 h Measured electric power at Best WBEP 89 0 89 0 W Nominal lighting power WL 4 4 W Average illumination of the lighting system on the cooking surface EMiddle 530 300 Lux Measured power consumption in standby PS 0 7 W Measured powe...