TABLE FOR THE INJECTORS
BURNERS
REGULATION OF THE MINIMUM FLAME
(FOR FITTERS USE ONLY)
NOTE:
The flame has been regulated for use with Natural Gas, however, when
converting to L.P.G. the flame may need adjusting.
Turn the thermostat to the maximum setting and pre-heat the oven, without grill pan
and base plate, for approximately ten minutes, turn the control to the 125 position.
Remove the knob and adjust the thermostat by-pass screw (Fig. 6) to obtain a short
sharp stable flame. (The flame is visible through the holes in the oven base).
Check that moving the control knob from the maximum flame position to the 125
setting, or rapidly opening and closing the oven door does not make the flame go
out.
G 30
- 28-30 mbar
G 20
G 31
- 37 mbar
20 mbar
OVEN
3,000
0,650
40
83
15 *
125
4 *
Nominal
Power
[kW]
Reduced
Power
[kW]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ring opening
[mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
GB
Cat:
II
2H3+
adjustable
*