Symbol

Units

Model Identification

CCA52

CCA72

Annual Energy Consumption

AEC

Hood

26.5

kWh

Time increase factor

f

1.7

FDE

Hood

9.4

EEI

Hood

69.0

Point

Q

BEP

94.7

m

3

/h

Point

P

BEP

136

Pa

Q

w

o

fl

r

i

a

 

m

u

m

i

x

a

M

MAX

206.4

m

3

/h

Measured electric power at Best 

W

BEP

38.0

W

Nominal lighting power

WL

4.0

W

Average illumination of the lighting 
system on the cooking surface

E

Middle

Measured power consumption in 
standby

P

S

N/A

W

mode

P

O

0.0

W

Sound power level

L

WA

63

dBA

GFE

Hood

49.1 (F)

%

LE

Hood

77 (A)

Energy Efficiency Information

Value

Lux

309

26.5

1.7
9.4

69.0

94.7

136

206.4

38.0

4.0

N/A

0.0

63

49.1 (F)

77 (A)

309

%

12

Summary of Contents for CCA52

Page 1: ...www cda eu CCA52 CCA72 Extractors Installation use and maintenance Cod 0103083595 00 04 ...

Page 2: ...e by someone who is responsible for their safety Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualified personnel Appliance information Please enter the details on the appliance rating plate below for reference to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes...

Page 3: ...tem or hot air ducting system Do not vent the extractor into an attic or loft space Only house the extractor in rooms with adequate ventilation Remember that the extractor is powerful and whatever air is extracted needs to be replaced Do not tile the extractor in It should be removable for service or maintenance Do not use silicone sealant to secure the hood to the wall You must be able to isolate...

Page 4: ...o run for approximately 15 minutes after the end of cooking Control Panel B Speed level buttons C Light button Press button C To switch on the extractor or to change the speed at any time when the extractor is running Press the relevant B button for the first second or third speed level as required Press the A button Fig 1 A B C ...

Page 5: ...removed and cleaned with warm soapy water You can also wash the grease filters in a dishwasher ensuring that the filters are put in an upright position to prevent damage from other items in the dishwasher After rinsing and drying replace the filter To remove the grease filter push in the button on the handle and then pull down on the filter at the front When you have released it at the front then ...

Page 6: ... cooker hood the charcoal filter should be replaced every 3 6 months dependent on use Note This charcoal filter is non washable and must be replaced as required To attach a new charcoal filrer follow the steps below 1 Remove the grease filter fig 3 I 2 Place the charcoal filter on the centre of the motor support Once firmly located turn the charcoal filter clockwise 90 degrees until the filter loc...

Page 7: ...ers are being used simultaneously or if your extractor is installed incorrectly lower than the recommended height This is normal and the extractor will work again once the motor has If your extractor is not working 2 Check that the fuse in the spur has not blown Contact CDA Customer Care A Customer Care Department The CDA Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949...

Page 8: ...w product is guaranteed against defects in materials and or workmanship Any parts found to be defective will be repaired or replaced at our discretion All repairs must be carried out by an authorised service engineer 8 ...

Page 9: ... top of the burners When the extractor is to be installed above a gas hob the minimum distance between the hob and extractor must exceed 700mm 7500mm is recommended The width of any hob must not be greater than the width of the extractor installed above it 4 g i F Installation When the extractor is to be installed above an electric hob the minimum distance between the hob and extractor must exceed...

Page 10: ...sions of the cut out based on your extractor 5 g i F I J E F G H D C B A A C D B 6 g i F A B C D CCA52 499 268 200 487 CCA72 679 268 200 667 CCA52 A B C D E F G H I J 518 499 515 480 260 274 200 282 173 10 CCA72 698 679 795 660 260 274 200 282 173 10 10 ...

Page 11: ...extractor into the cabinet opening and secure it with screws Secure the panel on with the 4 previously removed screws Fig 7 and insert the grease filter Connect the exhaust pipe to the ducting adaptor and locate on the extractor as indicated INSTALLATION 7 g i F 8 g i F 9 g i F 10 g i F 11 ...

Page 12: ... 9 4 EEIHood 69 0 Point QBEP 94 7 m 3 h Point PBEP 136 Pa Q w o fl r i a m u m i x a M MAX 206 4 m 3 h Measured electric power at Best WBEP 38 0 W Nominal lighting power WL 4 0 W Average illumination of the lighting system on the cooking surface EMiddle Measured power consumption in standby PS N A W mode PO 0 0 W Sound power level LWA 63 dBA GFEHood 49 1 F LEHood 77 A Energy Efficiency Information...

Page 13: ......

Reviews: