16
REVO C
2PH from 30A to 40A
User’s manual
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
REVO C 2PH
R
C
2
_
_
_
-
_
_
_
_
_
_
_
_
_
_
CURRENT
FUSES
4
5
6
description
description
code
30A
Fuse + Fuse Holder Included
0
3
0
35A
Fuse + Fuse Holder Included
0
3
5
40A
Fuse + Fuse Holder Included
0
4
0
MAX VOLTAGE
7
description
code
480V
4
600V
6
MAIN SUPPLY VOLTAGE
AUX VOLTAGE RANGE
8
description
description
code
100/120Vac
90 to 135V Vac
1
200/208/230/240Vac
180 to 265V Vac
2
277Vac
238 to 330V Vac
3
380/415/480Vac
342 to 528V Vac
5
600Vac
540 to 759V Vac
6
690Vac
540 to 759V Vac
7
INPUT
9
description
code
SSR
S
0:20mA
B
4:20mA
A
0:10V
V
10KPot
K
FIRING
START OPTION
10
description
description
code
Burst Firing
No Soft Start
B
Zero Crossing
No Soft Start
Z
CONTROL MODE
11
description
code
Open Loop
0
Voltage
U
Voltage Square
Q
Current
I
Current Square
A
Power VxI
W
OPTION
12
description
code
No Option
0
Option code, see code page table
...
FAN VOLTAGE
13
description
code
No Fan < 90A
0
APPROVALS
14
description
code
CE EMC For European Market
0
CUL us + CE EMC For American & European Market
L
LOAD TYPE
15
description
code
Normal Resistive Load with 3 Phase Star without neutral Connection
0
Normal Resistive Load with 3 Phase Delta Connection
1
IRSW Infrared Short wave with 3 Phase Star Connection
2
IRSW Infrared Short wave with 3 Phase Delta Connection
3
COMMUNICATION AND RETRANSMISSION
16
description
description
code
N°1 Modbus RTU
No Retransmission
0
Retransmission 4:20mA
1
Retransmission 0:10V
2
N°2 Modbus RTU
No Retransmission
3
Retransmission 4:20mA
4
Retransmission 0:10V
5
N°1 Profibus DP
No Retransmission
6
Retransmission 4:20mA
7
Retransmission 0:10V
8
N°1 Profinet IO
No Retransmission
9
Retransmission 4:20mA
A
Retransmission 0:10V
B
N°1 Modbus TCP
No Retransmission
C
Retransmission 4:20mA
D
Retransmission 0:10V
E
HB
WIFI
LOGGING
TOTALIZER
CODE
NOTES
Ø
HB
Alarm for partial or total load failure and Short Circuit on SCR (relay
output).
WiFi
Option that allows communication with a smart phone. From your
smart phone via the CD Automation App, direct to your thyristor unit
in the cabinet to read current, voltage, power and energy totalization
as well as the ability to change parameters to improve process and
product quality without opening the cabinet door.
APP
Free of charge download it from Google Play or Apple Store.
DATA LOGGER
This feature is important to see the historical data of
parameter like Current, Voltage and Power and can be useful to diagnose
a fault.
ENERGY TOTALIZER
This function totalize the energy consumption of
the load allowing the calculation cost of heat treatment.
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
5.2 Order Code
5.2.1 Option Code