background image

IMPORTANT    SAFETY    INSTRUCTIONS 

 

 

1.       Read these instructions. 
2.       Keep these instructions. 
3.       Heed all warnings. 
4.       Follow all instructions. 
5.       Clean only with dry cloth. 
6.       Do    not    block    any    ventilation    openings.    Install    in    accordance   

with    the manufacturer’s instructions. 

7.       Do   not   install   near   any   heat   sources   such   as   radiators,   heat   

registers, stoves, or other apparatus (including amplifiers) that produce 
heat. 

8.       Do not defeat the safety purpose of the polarized or grounding-type plug. 

A  polarized  plug  has  two  blades  with  one  wider  than  the  other.  A 
grounding  type  plug  has  two  blades  and  a  third  grounding  prong.  The 
wide  blade  or  the  third  prong  are  provided  for  your  safety.  If  the 
provided  plug  does  not  fit  into  your  outlet,  consult  an  electrician  for 
replacement of the obsolete outlet. 

9.       Protect   the   power   cord   from   being   walked   on   or   pinched   

particularly   at plugs, convenience  receptacles,  and  the  point   where  they 
exit  from   the apparatus. 

10.     Only use attachments/accessories specified by the manufacturer. 
11.      Use  only  with  the  cart,  stand,  tripod,  bracket  or  table 

specified  by  the  manufacturer  or  sold  with  the 
apparatus.  When  a  cart  is  used,  use  caution  when 
moving  the  cart/apparatus  combination  to  avoid  injury 
from tip-over. 

12.     Unplug this apparatus during lightning storms or when 

unused for long periods of time. 

13.     Refer  all  servicing  to  qualified  service personnel. 

Servicing  is  required   when  the  apparatus  has  been 
damaged in any way, such as power-supply cord or plug 
is damaged, liquid has been moisture, does  not  operate normally, or  has 
been dropped. 

14.    CAUTION  –  THESE  SERVICING  INSTRUCTIONS  ARE  FOR  USE  BY 

QUALIFIED  SERVICE  PERSONNEL  ONLY.  TO  REDUCE  THE  RISK 
OF  ELECTRIC  SHOCK  DO  NOT  PERFORM  ANY  SERVICING   
OTHER
 

THAN 

THAT 

CONTAINED 

IN 

THE 

OPERATING     

INSTRUCTIONS UNLESS YOU QRE QUALIFIED TO DO SO. 

15.   Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed 

  Class 2 power source only. 

 

 
 
 
 

iii 

Summary of Contents for HCAM675B

Page 1: ...COLOR DAY NIGHT CAMERA ART HCAM675B HCAM676B Please read this manual thoroughly before use and keep for future reference Via Don Arrigoni 5 24020 Rovetta S Lorenzo Bergamo http www comelitgroup com e...

Page 2: ...ce servicing instructions in the literature accompanying the product PRECAUTIONS Safety Should any liquid or solid object fall into the cabinet unplug the unit and have it checked by qualified personn...

Page 3: ...at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or t...

Page 4: ...RENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN E...

Page 5: ...al and national electrical and mechanical codes Carefully remove the color camera and its accessories from the carton and verify that they were not damaged in shipment The contents of the package incl...

Page 6: ...NTRODUCTION 1 CAMERA CONNECTION CONTENSTS of PACKAGE 2 CONTENTS of PACKAGE QUICK INSTALL 3 OSD MENU STRUCTURE 5 AUTO WHITE DEFECT LENS ADJUSTMENT 12 SPOT OUT JOY STICK KEY 13 EXTERNAL DIMENSIONS 14 SP...

Page 7: ...tronic shutter modes OSD On Screen Display Auto and manual white balance modes Auto BLC and HLC Day Night Auto 2D NR Smart IR Privacy Zone 4 point Motion Detection 4 Point MIRROR SHARPNESS HUE CONTRAS...

Page 8: ...2 CAMERA CONNECTION 1 Bullet Camera 2 Power power source from a DC 12V or AC 24V 3 Video BNC connector used to connect the camera to a monitor switcher ect...

Page 9: ...ion using the supplied drill guide label 2 Attach the bullet housing to the ceiling using suitable fasteners PTS M5 x 30MM screws are supplied only use if they are suitable 3 After bullet camera adjus...

Page 10: ...4 If something is disturbing Photo Sensor operation problem might be occurred...

Page 11: ...PICT ADJUST ATR MOTION DET NEXT page2 EXIT SAVE ALL LENS AUTO MANUAL SHUTTER AGC AUTO MANUAL WHITE BALANCE ATW PUSH USER 1 USER 2 ANTI CR MANUAL PUSH LOCK BACKLIGHT OFF BLC HLC PICTURE ADJUST MIRROR...

Page 12: ...ID LANGUAGE CAMERA RESET BACK page 1 EXIT SAVE ALL PRIVACY OFF ON DAY NIGHT COLOR B W NR NR MODE Y LEVEL C LEVEL RETURN CAMERA ID OFF ON LANGUAGE ENGLISH DEUTSCH FRANCAIS PYCCKNN PORTUGUES ESPANOL CAM...

Page 13: ...IRIS in SHUTTER AGC SHUTTER AGC AUTO HIGH LUMINANCE MODE SHUT AUTO IRIS AUTO IRIS Note only SHUT can be selected if LENS is in MANUAL mode SHUT AUTO IRIS is AE Auto Exposure for SHUTTER is 1 500 1 48...

Page 14: ...gain values for the outdoor fixed mode are used as the adjustment items of USER1 on the internal OSD menu B GAIN 0 255 R GAIN 0 255 ANTI CR Color rolling suppression MANUAL The B and R gain values fo...

Page 15: ...al joystick for 2secs and release MOTION AREA ON OFF Enables disables the motion detection AREA SEL 1 4 Selects the motion detection area Note set the area sel it would be better to move firstly BOTTO...

Page 16: ...and not mixed DAY NIGHT COLOR color only operation B W monochrome only operation BURST OFF ON Allows the color burst signal in monochrome to be removed if required IR OPTIMIZER OFF ON Smart IR mode OF...

Page 17: ...out changing the character CLR Inserts a space POS Allows you adjust the location of the camera ID title display if you move too much right side or down it might lose ID on the screen LANGUAGE LANGUAG...

Page 18: ...button for 5 seconds and enter Auto white defect menu Cover the lens and Enter for starting If white defects are over 65pcs the camera is faulty and auto defect is useless Over 70 C Auto white defect...

Page 19: ...13 Art HCAM676B HCAM675B Lens 5 50 mm 2 8 12 mm Angular Field of View HORIZONTAL 51 5 6 5 100 8 23 7 SPOT OUT JOY STICK KEY...

Page 20: ...14 EXTERNAL DIMENSIONS...

Page 21: ...ATR Adaptive Tone Reproduction LUMINANCE L M H CONTRAST L LM M MH H Backlight OFF BLC HLC Day Night AUTO Smart IR On Off Level MD Motion Detection On 4 areas Off Adjustable Size Sensitivity PM Privac...

Page 22: ...Via Don Arrigoni 5 24020 Rovetta S Lorenzo Bergamo http www comelitgroup com e mail export department comelit it...

Reviews: