background image

- 7 - 

Phone jack  
for ON/OFF  
control in  
manual mode 

Phone plug

Power supply 
(rear view)

 

Write sequence 

B8  (EXT) 

 

B11 (channel selection) 

 

 

 
 

 

 
 

1. External control mode (B8: EXT) outputs in negative logic (Low: L). 
2. The channel selection bit B11 output (Low: CH 1, High: CH 2) 

3. Light intensity data (B0 to B7) output in negative logic (Low: L) 
4. The write bit is output (data is written when the write signal is fall edge).     

Keep the write signal HIGH after the data is written. 

5. Data entry cycles must be 500µs or longer. 

 
 

 

ON/OFF control in Manual mode

 

1. In manual mode, the external ON/OFF control is available   

for the product. 

 

2. Insert the phone plug into the phone jack to send the   

ON/OFF control signal for manual mode. 
 

Note: Control is limited strictly to turning lighting ON and OFF.

 

Note: This option is not available when light intensity is externally   

controlled.

 

 

Phone jack (Ø3.5) signal line 

 

OFF

 

ON

 

 

 
 
 
 

Overcurrent protection

 

 
 
 
 

 

 
 
 

 
 
 
 
 

NPN open collector ON

 

>100µs 

>100µs 

NPN open collector OFF 

Light intensity data CH 1 

NPN open collector ON

 

Light intensity data CH 2 

>100µs 

CH.1 CH.2 

INT EXT 

B0 to B7 
( 8 bits) 

Write bit B9 

(WR) 

300µs 

300µs 

Overcurrent protection output 
The overcurrent protection output is a monitoring signal that 
becomes active when overcurrent is detected.    It is an output 
from bit B13.    Output circuit is an open collector, with negative
logic (active Low).

 

The product output stops if lighting current consumption (total 
of all channels) exceeds 107% of the rated current 
consumption.    Also, the error indicator lamp on the front panel
of the power supply will light and output cannot be resumed 
until the power supply is restarted.

 

>100µs 

Summary of Contents for PD2 Series

Page 1: ...y into the wall socket Please use the product within electricity voltage current specifications Otherwise it may cause fire and or electric shock Please unplug the power cord when connecting or discon...

Page 2: ...owing items for the Power Supply Always provide dedicated electric power source with stable voltage Sharing the electric power source with power devices such as inverters motors and so on may cause pr...

Page 3: ...ill be illuminated Turning ON lighting 1 Check the power supply switch to make sure it is turned OFF 2 Connect the LED lighting to the power supply 3 Plug the power cord of the power supply into a wal...

Page 4: ...he product for external control The product can be controlled externally using parallel bit control Close up view external control connector Intensity control knobs Power OFF 1 Turn the intensity cont...

Page 5: ...e to the power supply Also connect the lighting and any other devices 2 Input the desired control signal from the external control cable Note External control connector terminals are 0 V when low L an...

Page 6: ...teps using bits B0 to B7 and send the write signal to write bit B9 to write the light intensity data to the product Keep the write signal Low L for at least 300 s to write the data and switch the sign...

Page 7: ...is limited strictly to turning lighting ON and OFF Note This option is not available when light intensity is externally controlled Phone jack 3 5 signal line OFF ON Overcurrent protection NPN open co...

Page 8: ...th resistance Use a shielded cable of 3m or less for the control line Pin number Signal 1 Light intensity B0 LSB 2 Light intensity B1 3 Light intensity B2 4 Light intensity B3 5 Light intensity B4 6 L...

Page 9: ...tional 3m cables with plugs are available Note Please read instruction guide using optional cable 5 PD2 input circuit negative logic 6 Recommended control signal drive circuits opencollector switches...

Page 10: ...otection signal output circuit open collector 8 Dimensional Diagrams mm PD2 3012 2 A PD2 3024 2 A Output transistor VCEO 50V Ic 100mA Max current capacity 100mA We recommend usage at a load of 24 V 20...

Page 11: ...50 60Hz Inrush current typ 15A at 100V AC Note From a cold start Ground leakage current 3 5mAmax 264C 60Hz ith no load Output voltage rating 12V DC 24V DC Output current rating 2 3A total for 2 channe...

Page 12: ...Phone jack 3 5 mfd by Teishin electric mfg 2 Center signal line Sleeve GND External control 15 pin D sub plug with M2 6mm screws x1 Number 1 2 3 4 5 6 7 8 Structure B0 B1 B2 B3 B4 B5 B6 B7 Number 9 1...

Page 13: ...t scratch the unit by handling it with a hard object Do not let water or cleanser enter the unit Do not use cleansers or chemical agents other than those listed below For cleaning dampen a soft cloth...

Page 14: ...14 MEMO...

Page 15: ...15 MEMO...

Page 16: ...16 Copyright 2018 CCS Inc All Rights Reserved Descriptions in this instruction guide are based on information available as of May 2018 KZ01893 T001 005...

Reviews: