33
LAN cable
External Trigger Input Cable
(EXCB2-M10-3)
LAN cable
External Trigger Input Cable
(EXCB2-M10-3)
LAN cable
External Trigger Input Cable
(EXCB2-M10-3)
External Trigger Input Cable
(EXCB2-M10-3)
Firmly insert the connector of the LAN cable.
1
2
Press the lock and pull out the connector.
4
Connections
1
Connect the LED Light
Connect the connecting cable to the LED Light Unit to the output connector on the Control Unit.
Insert the connector to the Light Unit all the way in.
Press the lock and pull out the connector.
3
Connect the LAN Cable
(Provided by the user)
To perform external control, connect the LAN cable to the external control connector.
The LAN cable must be provided by the customer. (Cable length should be within 30 m
at aximum.) This product recognizes either cross-cable or straight-cable automatically
by auto-negotiation function. Please reboot the product when changing the cable.
4
Connect the External Trigger Input Cable
(Optional item, sold separately)
To use ON/OFF Mode or Strobe Mode, connect the external trigger input
cable to the external trigger input connector.
An optional External Trigger Input Cable (EXCB2-M10-3) (sold separately) is available.
In case using a self-made cable, cable length should be within 3 m at maximum.
Press the connector in until it locks in place.
Release the lock and remove the connector.
1
2
Before connecting the Control Unit, make sure that the main
power source is turned OFF. Making connections with the
power turned ON may result in a fire or electric shock.
WARNING
Connecting
Removing
Connecting
Removing
Connecting
Removing
1
2
1
Connect 24V DC Light Units to the 24V LIGHT output connectors, and Spotlights to
the HLV LIGHT output connectors.
Select the control mode and lighting mode from the following Application Guide and proceed to the indicated reference items.
The Light Units are always ON.
Power ON
Power OFF
Lit.
Not lit.
Control Mode
Lighting Mode
Application Guide
To use external control in Continuous Mode,
refer to items , , and under
.
1
3
2
8
Control with External Signals
To use manual control in Continuous Mode, refer to
items , , and under .
7
Manual Control
1
3
2
To use manual control in ON/OFF Mode,
refer to items , , and under
and
.
7
Manual Control
1
3
2
9
Inputting the External Trigger
The Light Units are turned ON for
a set time after the external trigger
signal is input.
Photocoupler OFF
Photocoupler ON
Lit.
Not lit.
Not lit.
* When the Trigger Logic
Switch is set to HIGH
Continuous Mode
ON/OFF Mode
Strobe Mode
Front panel operation
External control using a PLC
or image process device
The Light Units are turned ON or
OFF according to the external
trigger signal input.
Photocoupler OFF
Photocoupler ON
Lit.
Not lit.
Not lit.
* When the Trigger Logic
Switch is set to HIGH
5
What You Can Achieve with This Control Unit
* It is possible to turn LED light unit ON and
OFF by Ethernet communications, too.
External trigger signal or Ethernet
communications setting can be selected when
using ON/OFF mode by external control.
To use external trigger signal in ON/OFF mode,
refer to items , , and under
8
Control with External Signals
9
Inputting the External Trigger
1
2
3
and
.
To use Ethernet communications setting in ON/OFF mode,
refer to items , , , and under
1
2
8
Control with External Signals
3
5
.
To use manual control in Strobe Mode,
refer to items , , and under
and
.
9
Inputting the External Trigger
7
Manual Control
1
3
4
2
To use external control in Strobe Mode,
refer to items , , , and under
and
.
1
3
4
2
9
Inputting the External Trigger
8
Control with External Signals
(Only 24V DC Light Units can be set.)
(Only 24V DC Light Units can be set.)
2
Connect the AC Cord
Connect the power cord to the Control Unit and a wall socket. The Control Unit will turn ON when
power is supplied from the main power source. When the Unit is ON, the digital display will light.
Digital Display
The light intensity of the
lowest channel is displayed.
(Display when no Light
Unit is connected)
*Data that has been
set is retained even
after the power is
turned OFF with
manual or external
control.
1.0 mm
2
min.
100 MΩ
min.
250 V min., 10 A min.
2,000 VAC/minute
EN 60320-1 certified C13 type
Wire diameter
Line-to-line insulation
withstand voltage
Ratings
Withstand voltage
Socket standards
* If you would like to use the Control Unit with 200 to 240 VAC, you must procure appropriate AC power cord.
Recommended specifications
Socket