background image

33

LAN cable

External Trigger Input Cable

(EXCB2-M10-3)

LAN cable

External Trigger Input Cable

(EXCB2-M10-3)

LAN cable

External Trigger Input Cable

(EXCB2-M10-3)

External Trigger Input Cable

(EXCB2-M10-3)

Firmly insert the connector of the LAN cable.

1

2

Press the lock and pull out the connector.

4

Connections

1

Connect the LED Light

Connect the connecting cable to the LED Light Unit to the output connector on the Control Unit.

Insert the connector to the Light Unit all the way in.

Press the lock and pull out the connector.

3

Connect the LAN Cable

 (Provided by the user) 

To perform external control, connect the LAN cable to the external control connector.

The LAN cable must be provided by the customer. (Cable length should be within 30 m 
at aximum.) This product recognizes either cross-cable or straight-cable automatically 
by auto-negotiation function. Please reboot the product when changing the cable. 

4

Connect the External Trigger Input Cable

 (Optional item, sold separately)

To use ON/OFF Mode or Strobe Mode, connect the external trigger input 
cable to the external trigger input connector.

An optional External Trigger Input Cable  (EXCB2-M10-3) (sold separately) is available. 
In case using a self-made cable, cable length should be within 3 m at maximum.

Press the connector in until it locks in place.

Release the lock and remove the connector.

1

2

Before connecting the Control Unit, make sure that the main 
power source is turned OFF. Making connections with the 
power turned ON may result in a fire or electric shock.

WARNING

Connecting

Removing

Connecting

Removing

Connecting

Removing

1

2

1

Connect 24V DC Light Units to the 24V LIGHT output connectors, and Spotlights to 
the HLV LIGHT output connectors.

Select the control mode and lighting mode from the following Application Guide and proceed to the indicated reference items.

The Light Units are always ON.

Power ON

Power OFF

Lit.

Not lit.

Control Mode

Lighting Mode

Application Guide

To use external control in Continuous Mode, 
refer to items       ,       , and        under 

                                                               .

1

3

2

8

Control with External Signals

To use manual control in Continuous Mode, refer to 

items       ,       , and       under                                      .

7

Manual Control

1

3

2

To use manual control in ON/OFF Mode, 
refer to items       ,       , and        under 

                                     and 

                                                            .

7

Manual Control

1

3

2

9

Inputting the External Trigger

The Light Units are turned ON for 

a set time after the external trigger 

signal is input.

Photocoupler OFF

Photocoupler ON

Lit.

Not lit.

Not lit.

* When the Trigger Logic 

  Switch is set to HIGH

Continuous Mode

ON/OFF Mode

Strobe Mode

Front panel operation

External control using a PLC 

or image process device

The Light Units are turned ON or 

OFF according to the external 

trigger signal input.

Photocoupler OFF

Photocoupler ON

Lit.

Not lit.

Not lit.

* When the Trigger Logic 

  Switch is set to HIGH

5

What You Can Achieve with This Control Unit

* It is possible to turn LED light unit ON and 

OFF by Ethernet communications, too.

External trigger signal or Ethernet 

communications setting can be selected when 

using ON/OFF mode by external control.

To use external trigger signal in ON/OFF mode,
refer to items       ,       , and        under 

8

Control with External Signals

9

Inputting the External Trigger

1

2

3

and

.

To use Ethernet communications setting in ON/OFF mode,
refer to items       ,        ,       , and        under 

1

2

8

Control with External Signals

3

5

.

To use manual control in Strobe Mode, 
refer to items       ,       ,        and        under 

                                     and 

                                                            .

9

Inputting the External Trigger

7

Manual Control

1

3

4

2

To use external control in Strobe Mode, 
refer to items       ,       ,       , and        under 

                                                             and 

                                                             .

1

3

4

2

9

Inputting the External Trigger

8

Control with External Signals

(Only 24V DC Light Units can be set.)

(Only 24V DC Light Units can be set.)

2

Connect the AC Cord

Connect the power cord to the Control Unit and a wall socket. The Control Unit will turn ON when 

power is supplied from the main power source. When the Unit is ON, the digital display will light.

Digital Display

The light intensity of the 
lowest channel is displayed.

(Display when no Light 
 Unit is connected)

*Data that has been 

set is retained even 

after the power is 

turned OFF with 

manual or external 

control.

1.0 mm

2

 min.

100 MΩ

 min.

250 V min., 10 A min.

2,000 VAC/minute

EN 60320-1 certified C13 type

Wire diameter
Line-to-line insulation
withstand voltage
Ratings
Withstand voltage
Socket standards

* If you would like to use the Control Unit with 200 to 240 VAC, you must procure appropriate AC power cord.

   

Recommended specifications

Socket

Summary of Contents for Lighting Solution PD3-5024-4-EI

Page 1: ...eign matter from the electrodes Failure to do so may result in fire Do not connect any Light Units other than CCS LED Light Units Doing so may cause overcurrent and the device may overheat or ignite P...

Page 2: ...t outlets Insufficient ventilation may cause heat to accumulate inside the product and result in a fire Mounting the Unit to DIN Rail Mounting to DIN Rail Hook the tab on the upper part of the Unit on...

Page 3: ...us Mode refer to items and under 7 Manual Control 1 3 2 To use manual control in ON OFF Mode refer to items and under and 7 Manual Control 1 3 2 9 Inputting the External Trigger The Light Units are tu...

Page 4: ...rrent control Per connector 3 9 W max 700mA max Depends on the light intensity of the Light Unit Only connected Light Units can be selected Detected at any time 3 s 10 5 6 5 6 5 6 5 6 7 10 8 5 5 10 10...

Page 5: ...to turn ON the Light Units continuously To flash the strobe turn the setting switch and select a setting from F01 to F10 strobe time of 40 s to 40 ms The Light Units are turned ON for the period of ti...

Page 6: ...only 6 Lighting Mode Settings Select the lighting mode form Continuous Mode ON OFF Mode or Strobe Mode The lighting time can be set in Strobe Mode The Strobe Mode can be set for 24V DC Light Units onl...

Page 7: ...00N014FCRLF 02F07584CRLF Setting example Setting the L3 light intensity to 75 Send data Receive data when OK Receive data when NG when there is a command error Setting the Lighting Mode 4 01OF0CRLF 01...

Page 8: ...Units turn ON when the photocoupler is OFF and OFF when the photocoupler is ON Strobe Mode Photocoupler OFF Photocoupler ON Light Unit status Photocoupler OFF Photocoupler ON Light Unit status Photoc...

Page 9: ...wer sources with inverters motors etc may cause malfunction Do not bundle product cables with high voltage lines or power lines Doing so may cause the product to malfunction Keep the product cables as...

Page 10: ...10 15 70 VA 50 60 Hz 15 A at 100 VAC 30 A at 200 VAC from a cold start 3 5 mA max 264 VAC 60 Hz with no load 24V DC 1 500 VAC for one minute Cutoff current 10 mA 500V DC 20 M min Temperature 0 to 40 C...

Reviews: