17
Where, TT= 01 to 99.
In default TT = 09 x 10 = 90 Secs (80 secs talk time and 10 secs Alert Time)
To cancel the feature, dial from your own Extension #84#
Making 2 Junction lines talk to each other while Ext remains out of the conversation.
Process
:
During conversation with a Junction line - Hook-Flash - #6
(To park the Call)
– 0 – Tel No (who is to
be connected to the previous Junction call)
– Hook Flash - #
- Now all 3 party can talk to each other.
but Ext can keep Handset down. The 2 Junction lines will hear a tone after 2 minutes and if any of them
presses * then they can talk for another 2 minutes. Like this they can keep extending the talk time. If * is
not pressed then the calls will disconnect. If they wish to disconnect in between then any of them need to
dial #.
.
KTS DSS Key Setting
DSS Keys of KTS are programmable, they can be used as one touch CO access or Ext dialing.
To set CO Key as ext
, Dial: #*0000+ 23 K NN XX#
To set CO Key as Junction
, Dial: #*0000+ 23 K NN J#
To reset all CO keys of KTS ‘K’
, Dial: #*0000+ 23 K#
To clear particular CO Key of KTS ‘K’
, Dial: #*0000+ 23 K NN#
Where K = 1-4 (KTS number)
NN = 01-12 (CO number)
XX = 01-32 (Ext number)
J = 1-8 (Junction Number)
Default: All Keys are for Junctions
.
KTS Call Details
The incoming and outgoing call record of KTS can be viewed from the KTS. System stores 10 outgoing and 10 incoming
call details for each KTS.
Outgoing Call Details
With KTS on-
hook, press key ‘2’
Incoming Call Details
With KTS on-
hook, press key ‘8’
.
LCR (Least Call Routing)
– Manual
.
This feature allows the user to dial out telephone numbers through the cheapest Junction line.
In this mode, the user can pick particular Junction lines (of a Group) to make Junction calls.
Programming Procedure:
Dial #
0000 + 51 X #
Where X = 0 To enable Manual LCR mode
X = 1 To Disable LCR mode
Dial #
0000 + 51 0 # - To enable Manual LCR mode
Dial #
0000 + 51 1 # - To disable Manual LCR mode
Dial #*0000 + 53 J X1*X2*………*X16# - To add codes in LCR table for a Junction
Where J = 1-8 for Junction Number
X1…X16 = Max 4 digit code for storing in LCR table.
16 set of codes can be stored each with a max length of 4 digits.
If code is less than 4 digits, press * after the dialing the code for next code entry.
Dial #*0000 + 55 J# - To clear LCR table for a Junction.
Where J = 1-8 for Junction Number
When LCR Junction are busy-
Dial #*0000 + 54 1 # To allot other junction
Dial #*0000 + 54 0 # to give engage tone when LCR Junction is busy
Default: Allot engage tone when LCR Junction is busy
Dial #
0000 + 52 NN1 NN2 NN3…..NN5 # - To leave extensions out of LCR mode
NN1…NN5 = Last 2 digits of original Extension Number to be left out.
Max 5 extensions can be kept out of LCR.
Default: LCR mode is disabled.