background image

INFORMATION DISPLAY :

- production mode
- device set-up

LED INDICATORS :

- production in progress
- flow detected
- cover closed

Browse menus
Browse settings

VALID button

ZELIA ZLT : 

QUICK START

At first use, 

check that the flow switch into the cell is working properly.

When the filtration system is on, the flow light on the cell (middle) must be on. 
After 30 seconds the upper light (production) is on too. (example : it must be on 
P9)

Leave the production to work 

for 2 minutes

 then stop the filtration system.

Check that the flow light turns off

 and that the production light flashes. If  it 

doesn’t, check if  the flow switch is blocked. Leave the filtration off  for 2 to 3 
minutes.

Restart the filtration system (clock or 24h/24)

1

2

3

4

5

FLOW-SWITCH

CONTROL

For installation of  the salt chlorination cell, follow instructions in the

user guide

.

The unit must be protected with 

30mA differential

 residual current

protection.