background image

Technical instructions

Mini Brio X15CA

v1.0EN

www.ccei.ca

11

6.3. Electrical Connections

Installing this product could expose you to an electric shock. We strongly recom-
mend that you use a qualified professional. An installation error could put you at
risk and irreversibly damage the product and the equipment connected to it.

In compliance with the current National Electrical Code (NEC), underwater light-
ing must always be supplied with SELV (Safety Extra Low Voltage). Turn off the
power supply upstream before doing anything to the electrical installation.

Risk of Electrical Shock. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI). If you cannot verify that the circuit is protected by a
GFCI, contact a qualified electrician.

THE LED LIGHT AND PLASTIC NICHE FORM A COMPLETE NON-MET-
ALLIC LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION
DOES NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A
LISTED TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE
CURRENT NATIONAL ELECTRIC CODE (NEC).

The electrical connection must be performed dry,
in a sealed connection box whose cable glands
must be tightened in order to avoid any water in-
filtration.

Once startup and the operation tests are complete, it is recommended to drown the connection with a
reusable soft hydrophobic insulating gel. (ref. CCEI PNSP0002)

The soft external cable of this lighting system cannot be replaced.

If this cable is damaged, the lighting system must be disposed of or returned to the
manufacturer for possible reconditioning.

7.  Transformer power

The transformer to be used should have a sec-
ondary voltage of 12V (12.5V according to the
model). Its power should be in keeping with the
power of the projectors to be connected.

At any rate, the sum of the powers of the projectors
should remain below or equal to the power

Transformer power

Max. no. of X15

50

4

100

8

300

25

It is preferable to use power supplies from the same manufacturer.

Summary of Contents for Mini Brio X15CA

Page 1: ...ical features 3 3 Description 4 3 1 Warnings 4 3 2 Technical support 4 4 Use Autonomous mode 5 5 Safety 5 6 Installation 6 6 1 Wall through installation 6 6 2 Placement in a wall 10 6 3 Electrical Con...

Page 2: ...Depending model 4 6m 15ft 15 2m 50ft 30 4m 100ft Wall through Depending model Wall through PF10R191 for fiberglass or concrete pool supplied with 2 gasket 2 locknut Wall through PF10R192 for liner poo...

Page 3: ...maximum according to colour Weight Cable lenght Projector only Complete box 4 6m 15ft 0 5kg 1 1lb 1 2kg 2 6lb 15 2m 50ft 1 2kg 2 6lb 1 9kg 4 2lb 30 4m 100ft 2 2kg 4 4lb 2 9kg 6 4lb LED type 3 powerfu...

Page 4: ...des and ordinances must also be adhered to Improper installation will create an electrical hazard which could result in death or serious injury to pool users installers or others due to electrical sho...

Page 5: ...Random sequence 1 18 Sequence Random sequence 2 Change of mode The mode can be changed by cut ting the power supply of the pro jectors for a very short space of time less than 1s By successive interr...

Page 6: ...EN www ccei ca 6 6 Installation 6 1 Wall through installation 6 1 1 Fiberglass pool Prior to installing drill a hole in the pool using a 60 mm 2 3 8 in diameter cylinder saw The wall through is connec...

Page 7: ...Technical instructions Mini Brio X15CA v1 0EN www ccei ca 7 6 1 2 Concrete pool Assemble a pipe of sufficient length with a 1 5 threaded coupling onto the wall through before sealing the assembly...

Page 8: ...s Mini Brio X15CA v1 0EN www ccei ca 8 6 1 3 Concrete liner pool Assemble a pipe of sufficient length with a 1 5 threaded coupling onto the wall through before sealing it Then glue a first gasket befo...

Page 9: ...a 9 6 1 4 Panels liner pool Prior to installing drill a hole in the pool using a 80 mm 3 1 8 in diameter cylinder saw Think to glue the first liner gasket before installing it The wall through is conn...

Page 10: ...e installed in a threaded 1 5 niche ref PF10R191 or PF10R192 We recommend that installation is performed by a professional 6 2 1 In wall through 1 Pass the gasket and the projector cable through the w...

Page 11: ...DOES NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A LISTED TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE NEC The electrical connection must be performed dry in a...

Page 12: ...I Inc Qu bec 1170122155 declares that the product Mini Brio X15CA satisfies the safety and electromagnetic compatibility requirements of Euro pean directives 2006 95 EC and 2004 108 EC and is UL liste...

Reviews: