Technical instructions
Mini Brio X15CA
v1.0EN
www.ccei.ca
11
6.3. Electrical Connections
Installing this product could expose you to an electric shock. We strongly recom-
mend that you use a qualified professional. An installation error could put you at
risk and irreversibly damage the product and the equipment connected to it.
In compliance with the current National Electrical Code (NEC), underwater light-
ing must always be supplied with SELV (Safety Extra Low Voltage). Turn off the
power supply upstream before doing anything to the electrical installation.
Risk of Electrical Shock. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI). If you cannot verify that the circuit is protected by a
GFCI, contact a qualified electrician.
THE LED LIGHT AND PLASTIC NICHE FORM A COMPLETE NON-MET-
ALLIC LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION
DOES NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A
LISTED TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE
CURRENT NATIONAL ELECTRIC CODE (NEC).
The electrical connection must be performed dry,
in a sealed connection box whose cable glands
must be tightened in order to avoid any water in-
filtration.
Once startup and the operation tests are complete, it is recommended to drown the connection with a
reusable soft hydrophobic insulating gel. (ref. CCEI PNSP0002)
The soft external cable of this lighting system cannot be replaced.
If this cable is damaged, the lighting system must be disposed of or returned to the
manufacturer for possible reconditioning.
7. Transformer power
The transformer to be used should have a sec-
ondary voltage of 12V (12.5V according to the
model). Its power should be in keeping with the
power of the projectors to be connected.
At any rate, the sum of the powers of the projectors
should remain below or equal to the power
Transformer power
Max. no. of X15
50
4
100
8
300
25
It is preferable to use power supplies from the same manufacturer.