HPS-2971
Please check register values before modifications.
Register number Name
Limits
Description
Default
96
STBY 00
03 Standby
01
97
IDET
00
02 Mute action
00
98
INI
00
00 Initialization
0
99
VSD 00
00 Screen adjust
0
Register 96 (STBY)
Register 97 (IDET)
Value
Description
Value Description
0
TV always turn on after
POWER ON.
0
The audio/video mute
is activated after a
delay, when the lost of
horizontal sync is
detected.
1
TV alwats returns to
STANDBY after POWER
ON
1
When the lost of
horizontal sync is
detected, audio mute
is not activated.
2 e 3
FACTORY VALUES
ONLY. DO NOT USE
THESE VALUES.
2
The audio/video mute
is activated
immediately, when the
lost of horizontal sync
is detected.
Register 98 (INI)
Register 02 & 99 (VSD)
Value
Description
Value Description
-
This register returns all
registers to factory
default value. Tip: Take
note of all current
register values before
use of INI register (it will
return all values to
default) to ease a future
adjustment.
-
Screen adjust (See
item 4.5 – Mode 2)