HPS-2007
13
2.3.2
Frame centralization
Preparation:
a)
Connect the receiver under test to a 117 V
AC
line.
Turn On the TV and position the bright and contrast control to the maximum, and the
saturation and volume controls to the minimum position. Wait for a pre-heating period.
b)
Apply a CIRCLE pattern 60dB
µ
V signal with 88% modulation ( The preferred channel will
be define by the fabric unit ).
c)
Position to “nominal” the bright and contrast controls.
d)
For the next reading, please observe the figure B.
e)
Observe the image and make the measures (in centimeters) of the distances a, b, c and d.
f)
Apply the following formula to calculate the horizontal centralization.
(a/b)-(d/c)
g)
Observe the image and make the measures (in centimeters) of the distances p, q, r and s.
h)
Apply the formula to calculate the vertical centralization.
(p/q)-(s/r)
Minimum
Nominal
Maximum
Unit
|(a/b)-(d/c)|
-
0,00
0,10
|(p/q)-(s/r)|
-
0,00
0,20