Step 3

: Next, verify that the two solenoid plungers 

are properly aligned with the CLOSE and TRIP 

buttons as shown on the figure to the right.  If they 

are not, adjust the location of the solenoids until 

they are properly aligned.  The recommended 

distance from the plunger to the pushbutton is 

1/8”.  

 

 
 

 

Step 4

: Next, pull the charging arm out away from 

the breaker and place the black composite handle 

adapter over it.  Press the adapter onto the changing 

arm until it fits firmly and completely over the 

charging arm as shown to the right.

 

 

 

 

 

 

 

 

 

 

Step 5

: Connect the charging linkage to the handle 

adapter by inserting the rod-end into the clevis and 
aligning the hole (Manual rotation of the motor arm 
may be necessary).  Next, insert the clip through the 
rod-end and clevis and press the fitted end of the clip 
over the clevis to secure the linkage in place. 
 
The RSA-180 is now properly installed and ready for 
operation. 
 
 
 
 
 
 