15 OF 20
Audit Trail Parameters
Three separate incrementing, non-resettable audit trail parameters are used by
the M660 to indicate changes to various parameters:
• P60201
–
OIML
•
P60203 – Calibration
•
P60204 – Setup
An audit trail counter will increment only once upon exiting the Setup Mode and
saving changes regardless of how many settings were changed. Each audit trail
counter will increment to 99999 before beginning again at 00001.
DO NOT ATTEMPT TO ACCESS AUDIT TRAIL PARAMETERS DURING
CRITICAL WEIGHT PROCESSING! Weight conversions and custom transmits
will be suspended and all setpoints will be deactivated!
Accessing Audit Trails
The audit trails may be accessed from the Weigh Mode. An access code is not
required to view audit trail parameters.
To access audit trails:
1. Key in
60201 [SELECT]
to access the OIML audit trail.
2.
. Key in
60203 [SELECT]
to view the Calibration audit trail.
3. Key in
60204 [SELECT]
to view the Setup audit trail.
4. Press
[ZERO]
to return to the Weigh Mode.
Calibration Audit Trail
Any changes to the existing calibration will increment the Calibration audit trail at
P60203. This includes any changes to P60101 Æ P61140 of the information
parameters.
Setup Audit Trail
Changes to any of the Setup Mode parameters will increment the Setup audit
trail at P60204.