If you want to use Alarm Input, the types of sensors must be selected in OSD menu. The
sensor types are divided into Normal Open and Normal Close. If wrong sensor types are
selected, alarms should be activated reversely to sensor inputs.
~
Normal Open
Output Voltage is high state when sensor is activated
~
Normal Close
Output Voltage is high state when sensor is not activated
Relay Output
The maximum loads are as follows.
Power Type
DC Power
AC Power
Maximum Load
MAX. DC 24V, 1A
MAX. AC 125V, 0.5A