CB Svendsen TeleSwitch M2 Installation And User Instructions Download Page 2

M a n u a l a c t iv a t in g  o f  o u t p u t

  in d ic a t io n  in p u t  a k t iv a t e d  

C o d e

" P o w e r  O n "

C h a n n e l 1

C h a n n e l  2

P r o g r a m m in g  a n d  in d ic a t o r  

Installation: 

 
230V mains power is connected to terminals 23 and 24 
The ground wire is connected to terminal 15 
This provides extra protection against 
lightning. 
 
The equipment that is to be controlled 
(e.g. an electric heater) is connected to one of 
the 

 

2 outputs on the unit. 

 

 

See the example below where an 

 

appliance is connected to output 2. 

 

Output 2 is a potential-free connection. 

 

Mains power can be connected to output 2 
by connecting terminal 22 to terminal 24. 
The equipment wiring is connected to 

 

terminals 21 and 24 respectively.  

 

 
If another appliance is to be controlled, this can be done at output 1.  
Output 1 is also a potential-free connection. 
Mains power can be connected to output 1 by connecting terminal 20 to terminal 23. 
The equipment wiring is connected to terminals 19 and 24 respectively.  

 

 
If appliance is to be connected that requires a different voltage 

(e.g. a 12V battery

the voltage supply must come from outside the 

TeleSwitch

 unit.

 

 

                                                                       

 

 
 

If the inputs are to be used 

(message or alarm) 

 

a potential-free contact is connected to

 

 

input 1 at terminals 16 and 18, and for 
input 2 at terminals 17 and 18. 

 

 
 
 
 Note! 

 Inputs 1 and 2 have a common terminal (18). 
 The installation can be tested on site.  

 
 

     

 

 

 

       

 
 
 
 
 
 
 
 

 

Programming: 

 
TeleSwitch

 is programmed so that it can control 

(switch on/off, start/stop)

 or report back 

(closed/open, message/alarm switch)

 via the telephone network. 

 

The following settings can or should be programmed: 

 

        Number of rings (1 to 9) from a telephone to 

TeleSwitch

 

before it ”answers”. 

 

            

TeleSwitch

 should be programmed to answer after several rings  

             (4 rings are recommended)

 so that possible wrong number calls are avoided. 

,

 A telephone number to which 

TeleSwitch

 is to ring if input 1 is activated and 

 

            another telephone number if input 2 is activated.  
            However the same telephone number can be selected for both inputs.  

       Mode for the individual function channel. 

TeleSwitch

 has 2 function channels, and each  

channel can be set to be either an output or an input. See the next page. 

       A four-digit security code so that the person or persons who know 

 

           the security code can program or control and check the 

TeleSwitch

.  

 

         On leaving the factory the 

TeleSwitch

 is preset as follows: 

        

       4 rings before the 

TeleSwitch

 responds. 

        

,

   No telephone numbers have been selected for inputs 1 and 2. 

        

       Mode 4, meaning 

Channel 1

 and 

Channel 2

 are programmed to be outputs 

        

       The security code is initially 4-3-2-1. 

 
 

Staring programming: 

 

-

 

Connect the mains power plug to the mains power outlet. 

 

-

 

Connect the 

TeleSwitch

 by means of the supplied telephone cable 

 

       to the telephone jack 

(in parallel with any existing telephone or fax)

 and 

       press the 

Code

 button on the 

TeleSwitch

 

-  

     

the

 Code

 LED will light, providing that the 

TeleSwitch

 is ready for programming. 

         (If the Code button is pressed by mistake, the TeleSwitch may go out and light again 

or perform a call to the TeleSwitch and when it responds, cuts off). 
 

-

 

TeleSwitch

 is now ready to be programmed. 

 

Ring now to 

TeleSwitch

 from a different telephone 

(touch-tone with buttons)

 or preferably from 

a mobile phone.  

Note! A telephone plugged into the same telephone jack as the 

TeleSwitch 

cannot be used 

for  programming: 

 

-       

TeleSwitch

 will respond with a "ding - dong" signal after which begin by pressing... 

 
 
 

 

 

star       

number of setting        Star         value for  setting 

finish by pressing 

” #” 

                                   (

 



)

 

which                              (when programming         

                                  is to be programmed                    the security code enter 4 digits) 

2

4

2

3

2

2

2

1

2

0

1

9

1

8

1

7

1

6

O u t  2

M e s s a g e /a l a r m

C h a n n e l   2

M e s s a g e / a l a r m

C h a n n e l   1

O u tp u t

2

2 3 0

V

A C

O u t 1

In

 1

In

 2

C
o

m

P h o n e

L in e

1

5

G r o u n d

N e t 

2 3 0 V

G
ro

u

n

d

Connect 

TeleSwitch

 to a 230V mains power 

supply and push the buttons for 

Channel 

and/or 

Channel 2. 

 

 See if the connected devices are extinguished. 
The LEDs indicate whether the outputs are lit or 
extinguished.   
 

 

                2 
 

 

2

4

2

3

2

2

2

1

2

0

1

9

1

8

1

7

1

6

O u t  2

O u tp u t  2

2 3 0

V

A

C

O u t 1

In

 1

In

 2

C
o

m

P h o n e

L in e

1

5

G r o u n d

N e t 

2 3 0 V

G
ro

u

n

d

C o n n e c t e d   d e v i c e

c o n t r o l l e d   b y   o u t p u t  2

C o d e

L E D

C o d e  b u t t o n