background image

Connect the 3 wires to the power supply: Live 

feed (L1), neutral (N), earth (     ). 

Screw the mounting base on the ceiling. 

Screw the power supply on the mounting base.

Once the mounting base with power supply is 

installed, attach the alarm by twisting clockwise 

until it clicks. 

 

 

 

 

 

 

 

 

 

 

OPTION 2: ALARM MOUNTED ON TOP OF 

CONDUIT BOX:

Connect the 3 wires from the conduit box on the 

alarm power supply:

Live feed (L1), neutral (N), earth (    ).

 

 

 

 

 

Screw the power supply on conduit box.

NOTE: Mounting base is not used when 

the alarm is installed on conduit box. 

6. SAFETY LOCK:

7. TEST FUNCTION:
After installation, and at least once per quarter, 

test all of your alarms to ensure they are operating 

correctly and are within range of each other.
It is recommended to check visually every week if 

the LED flashes correctly (every 48sec.).

Press the test button on any alarm for at least 

10 seconds.This will send out a test signal 

from the alarm; all other connected alarms 

should receive the signal within a short time. 

The alarms will emit a short beep and the LED 

will flash every 8 seconds for 2 minutes. 

NOTE: Test function also transmits a weaker RF 

signal to ensure an optimal operation in normal 

conditions.

When the test signal is sent out, the alarms will 

respond in two ways:
1. A single beep every 8 seconds indicates that 

the alarms are connected and functioning.

2. Three short beeps every 8 seconds indicates a 

smoke sensor fault. The alarm should be cleaned 

by running the vacuum (on a low setting) around 

the smoke alarm chamber and tested again.

For cathedral or peak ceiling: 

5. INSTALLING THE SMOKE ALARM: 

NOTE: THIS ALARM NEEDS TO BE INSTALLED 

BY A PROFESSIONAL.

MAKE SURE ELECTRICITY IS SWITCHED OFF 

BEFORE STARTING THE INSTALLATION.

CAUTION: LIVE, NEUTRAL AND EARTH MUST 

BE CORRECTLY INSTALLED AND NOT MIXED UP.

NOTE: The alarm is delivered in the packaging 

with a dust cover, installed to protect the alarm for 

exposure to excessive dust which could potentially 

damage or reduce the function of the alarm while 

the building is under construction. The dust cover 

must be removed after the building is fully cleaned.

OPTION 1: ALARM MOUNTED ON MOUNTING 

BASE OUT ON THE CEILING:

Use the mounting base ring to mark the screw 

holes on the ceiling.

For surface wiring pass the feed wire through 

the mounting base cable holder and screw after 

termination. 

2

MARK UP 

4 SCREW HOLES 

WITH A PEN

L1

L2

N

L2

N

L1

USE THE 

ENCLOSED 

SCREWS AND 

PLUGS

Peak ceiling

Minimum 60cm 

from peak

Mount the

safety lock