RF connection is done with the device powered 

with battery only. You do not have to connect the 

power supply. The product label must not be re-

moved as it contains important information re-

garding the product.

All alarms to be connected in the house should 

be put into ‘Learn Mode’ by sliding the switch on 

the back of the alarm to the ‘Learn Mode’ position.

Please note: The learn switch placed on the back 

of the alarm can only be in learn position when 

the alarm is disassembled from the power supply 

unit. The learn switch will automatically switch to 

normal position when the alarm head is fitted to 

the power supply.

The red LED will light up to indicate that ‘Learn 

Mode’ has been selected. 

Press and hold  the test button at one alarm only, 

until it beeps and the LED flashes. This alarm will 

become the master and will start sending out a 

specific house code to the other alarms.

As  the  other  alarms  receive  the  specific  house 

code, they will also flash the LED light.

When  the red LED light flashes on all alarms, 

they are connected and MUST BE SWITCHED 

OUT OF ‘LEARN MODE’ and installed. 

Label the original “Learn” alarm in order to easily 

add new CAVIUS Wireless Family alarms to the 

system.

2. THE BEST AREAS TO INSTALL THE SMOKE 

ALARM:

• Note the local country regulations regarding 

installation. 

• Note the local regulations about information 

to your insurance company regarding installed 

smoke alarms.

• Install an alarm between possible fire sources 

and bedrooms as a minimum.

• Install alarms on each floor of the house, in 

hallways and landings. 

• Alarms in each room such as bedrooms and 

living rooms.

Additional alarms increase the security. 

3. AREAS WHERE NOT TO INSTALL SMOKE

ALARMS:

• In dusty rooms
• At the top of a high pointed ceiling, in ceiling 

corners, and within 50cm of a wall.

• In rooms where temperature goes outside the 

range +4

o

 to 38°Cor above 90% relative humidity 

not condensing.

• In kitchens, garages, laundries, or too close to 

fireplaces; areas where either dampness, gases 

or smoke could occur.

Place the alarm where it is reachable in order to 

test the alarm and for maintenance.

4. PLACEMENT:
The smoke alarm is designed to be installed on a 

ceiling. With a minimum of one smoke alarm per 

floor  and  a  maximum  distance  between  smoke 

alarms of 10 meters.
For ceiling installation:

The smoke alarm should be a minimum of 30cm from 

the wall. 

Mains powered smoke alarm device

Commercial reference: 2208

Developed by CAVIUS

The smoke alarm is designed for private homes.

PLEASE READ THE INSTALLATION GUIDE 

CAREFULLY BEFORE INSTALLATION AND 

RETAIN FOR FUTURE USE.

SAFETY INSTRUCTIONS:

The device comes with a 3V lithium battery. Bat-

teries are to be handled with care and battery pow-

ered devices should be kept out of reach of chil-

dren. Do not try to recharge or burn the batteries. 

TECHNICAL INFORMATION:

Powered by a non-replaceable 3V CR123 Lith-ium 

battery with 10-year life (included).

 

It can be RF interlinked with other CAVIUS 

Wireless Family alarms.

The maximum number of alarms that can be 

interlinked within a house group are 32. Please 

note: These must be alarms from the CAVIUS Wire-

less Alarm Family. 

 

The distance between interlinked alarms depends 

on the house layout and they should always be 

tested after installation. It is not advised to install 

alarms with a separation of more than 10m.

Diameter: 97mm. Height: 41mm (without mount-

ing base) 52mm (with mounting base).

Certified  to: EN14604:2005 + AC:2008, EN300-

220, EN50130-4:2011, EN60065. EN60950-1, 

RoHs, Reach. 

1. HOW TO SET UP AND CONNECT ALARMS: 
Start by pulling out the battery isolation strip as 

shown. 

UK

1

Minimum 30cm 

from wall

Wall

Ceiling

CHAMBER

FILTER

TEST BUTTON

SOUND 

OUTPUT

RED & GREEN LED

Optical

Siting of Optical Smoke alarms

INSTALLATION

G U I D E

ISOLATION 

STRIP

NORMAL MODE

2

LEARN MODE

1

2

1