6–Boot from SAN Configuration
iSCSI Boot from SAN
82
BC0154501-00 P
Cavium recommends that you disable the Integrated RAID Controller.
Selecting the Preferred iSCSI Boot Mode
To select the iSCSI boot mode on Windows:
1.
On the NIC Partitioning Configuration page for a selected partition, set the
iSCSI Offload Mode
to
Enabled
.
2.
On the NIC Configuration page, set the
Boot Protocol
option to
UEFI iSCSI
HBA
.
Configuring iSCSI General Parameters
Configure the QLogic iSCSI boot software for either static or dynamic
configuration. For configuration options available from the General Parameters
window, see
, which lists parameters for both IPv4 and IPv6.
To set the iSCSI general parameters on Windows:
1.
From the Main Configuration page, select
iSCSI Configuration
, and then
select
iSCSI General Configuration
.
2.
On the iSCSI General Configuration page (see
),
press the DOWN ARROW key to select a parameter, and then press the
ENTER key to input the following values (see
descriptions of these parameters):
TCP/IP Parameters via DHCP
:
Disabled
(for static iSCSI boot), or
Enabled
(for dynamic iSCSI boot)
iSCSI Parameters via DHCP
: Disabled
CHAP Authentication
: As required
IP Version
: As required (IPv4 or IPv6)
Virtual LAN ID
: (Optional) You can isolate iSCSI traffic on the network
in a Layer 2 vLAN to segregate it from general traffic.To segregate
traffic, make the iSCSI interface on the adapter a member of the
Layer 2 vLAN by setting this value.
Configuring the iSCSI Initiator
To set the iSCSI initiator parameters on Windows:
1.
From the Main Configuration page, select
iSCSI Configuration
, and then
select
iSCSI Initiator Configuration
.
2.
On the iSCSI Initiator Configuration page (see
select the following parameters, and then type a value for each:
IPv4* Address
IPv4* Subnet Mask