background image

Striker 
face plate

Striker face 
plate screws

11

11

Position the striker face plate in the 

centre of the striker body - this may need to 
be adjusted in the steps following. Insert the 
striker face plate screws and loosely tighten.

12

Close the door. When the striker is fitted 

correctly the magnet will draw the plunger 
forward. If this does not happen the striker is 
misaligned with the plunger (see below). 
If the alignment is correct, tighten the screws 
and skip to Step 14; otherwise continue to 

Step 13.

12

13

Striker 
face 
plate 
screws

2.5mm 

(3/32”)

2.5mm 

(3/32”)

Striker

Plunger

13

The striker allows 2.5mm (3/32”) of 

adjustment in each direction when the 
striker face plate is fitted in the centre of  
the striker body.
To adjust the face plate position, loosen the 
striker face plate screws slightly and adjust 
the face plate up or down to allow the 

Plunger 
flats

14

Manually push the plunger forward until 

there is no gap between spring reservoir one 
(SR1) and spring reservoir two (SR2).
Restrain the plunger nut using the large end 
of one of the two identical supplied spanners.

Push 
here

14

Turn 
clockwise

15

15

Place the small end of the second spanner 

across the flats under the head of the plunger.
Keep the spanner restraining the plunger nut 

stationary while turning the second spanner 

clockwise.
Continue to turn the spanner until there is no 
longer a gap between the spanner and the 
chassis. 
Now turn the spanner anti clockwise half a turn. 
The plunger should now be adjusted correctly. 
Slide the door closed to check. 
Adjust if necessary.

Gap

No 
gap

16

Fit the remaining side handle (with 

visible handle joining screws fitted) to 
the chassis by sliding the front flange of 
the handle under the heads of the 3x side 
handle to chassis screws. 
Tighten the screws.

16

18

Fit the passage face plate to the chassis 

using the 3x face plate screws.

17

Use the ball end of the CL400 Allen key to 

tighten the 2x handle joining screws. 
Use the other end of the Allen key to firmly 
tighten the screws. 

8

8

Remove the striker from its box. Remove 

the striker face plate from the striker body. 
Insert the 2x striker nuts into the recess in the 
back of the striker body.

Insert the 2x striker face plate screws through 
the slot in the front face of the striker body 
and into the striker nuts. Loosely tighten the 
screws.

Striker nuts

Striker 
nuts

Rear View

Striker 
body

7

Open the door. Transfer the horizontal line 

across the centre of the closing jamb. This 
line represents the top of the striker cut out.
A double-sided striker cut out template 
has been provided. Use the ‘FLUSH striker 

template’ and instructions to router out the 
recess in the closing jamb.

32 40

32 40

40 32

40 32

2

3

7

CL

5

4

6

Horizontal 
line

Striker 
template

Centre of 
closing jamb/
centre of 
door closing 
position

CL

7

Striker 
body

Striker face 
plate screws

Striker 
mounting 
wood 
screws

9

Striker face plate 
screws

9

Insert the striker body, with the striker 

face plate screws and the striker nuts 
attached, into the cut out in the closing 
jamb. 

Striker 
face 
plate 
screws

10

10

Remove the striker face plate screws.  

The striker nuts are now trapped in position.

5

7

6

PAGE

PAGE

PAGE

Front 
flange

Face 
plate 
screws

Passage 
face plate 

© Cavity Sliders Limited. CAVILOCK

®

 CL400

®

 MAGNETIC (O.D. 2013) ADA PASSAGE INSTRUCTIONS.  

61229/CL405ZA920 - 02.2018

All copyright and other property in this document is reserved by Cavity Sliders Limited. Details and specifications are subject to 

change without notice. Whilst all care is taken to ensure the accuracy of all information, no responsibility will be accepted for any 

errors or omissions. ® CS FOR DOORS, CS CAVITY SLIDERS and CAVILOCK are Registered Trademarks. Patents pending.

18

17

19

If you are installing a CL400 Bi-Parting - 

Passage (Non Latching) handle, both handles 

are the same and you can simply repeat the 
Passage Handle installation instructions for the 
second door.  

Ignore any reference to the striker or plunger.

8

PAGE

Fitting the Remaining Side Handle

Adjusting the Plunger

Fitting the Face Plate

Bi-Parting Handles

Adjusting the Plunger

Screw the 4x striker mounting wood screws 
into the closing jamb.

Spanner

Spanner

Plunger 
nut

Plunger

plunger to penetrate the striker face plate. If 
the plunger still fails to penetrate the striker face 
plate, the door height may need to be adjusted.

Fitting the Striker

Fitting the Striker

Cavity Sliders Limited 
Auckland Head Office
5 - 7 Rakino Way  
Mt Wellington
Auckland, NZ

T  +64 9 276 0800
F  +64 9 276 2525
[email protected]

Recyclable 

Packaging

www.csfordoors.co.nz

www.cavitysliders.com.au

www.cavitysliders.com

SR1 SR2

No gap

CL400 
Allen key

M3.5 

handle 

joining 

screws

M3.5 

handle 

joining 

screws

Reviews: