© 2013 O&M Manual Version 2.0 CaviDyne
TM
5077 Fruitville Rd.; Ste 109-157
Sarasota, FL 34234 U.S.A.
Phone 352.275 5319
Page 23/26
6.1 Basic Preventive Maintenance Recommendations
After
Every
Use
Every 6
Months
or 125
Hours*
Every 12
Months
or 250
Hours*
Every 12
Months
or 500
Hours*
Every
1,000
Hours
Ensure pump and oil pressure
accumulator are filled with oil
X
Check water inlet strainer
cartridge(s) and clean if
necessary
X
Inspect hoses for wear or
damage
1
X
Replace pump oil
2
X
Check pump valves and seals
for wear & change if necessary
X
* Whichever occurs first.
1) If any hose damage if found, replace hose immediately.
2) The initial oil change is required after 50 hours of operation.
See pump manufacturer’s
literature
in the Appendix for additional recommendations.
6.3 Pump Service
The high pressure water pump requires minimal maintenance. The pump oil
should be checked on a regular basis. The pump crankcase should be
COMPLETELY FILLED with SAE 30 viscosity non-detergent oil. See pump
ma
nufacturer’s literature found in the
APPENDIX
for further information.
6.4 Inspection/Cleaning of Water Inlet Strainer
The water inlet strainer should be inspected and cleaned after each use of the
CaviBlaster
®
2040-ROV.
This space intentionally left blank