1. Inspect the system for damage. Clean the inlet strainer. Check oil/fuel
levels.
2. Attach all hoses to the unit and connect the feed pump electrical cable.
3. Start the feed pump or alternate water supply and ensure that the system is
primed.
4. Attach the gun to the pressure hose.
5. Make sure that the diver is ready to work and that the gun is submerged in
the water.
6. Apply hearing protection, start the engine and adjust the throttle to
“MAX.”
7. Activate the cleaning cavitation stream by squeezing the gun trigger to
open or “on.”
8. Proceed with cleaning, and then when finished...
9. Stop the feed pump, Lower throttle and stop the engine.
10. Release pressure from the hose(s) by squeezing the gun
trigger to the open or “ON” position
while under water
.
11. Remove the gun from the water.
12. Flush the system and rinse the outside of the power unit with fresh
water.
WARNING
Page -
12
CaviBlaster 1325-GSS Operations Manual
For More information please email [email protected] or call 1-(352)275-5319