VII – Routine Maintenance of the CaviBlaster System
1. Empty and clean the inline strainer every day. (figure # 1).
2. Check the oil level and consistency in the engine and pressure pump every day. (figure
# 2 and Figure # 3)
3. Flush the system and rinse the power unit with fresh water after each days use, for at
least 5 minutes, to make sure all inside residuals are removed.
4. Inspect the pump drive belt every week and replace the belt when cracking appears.
5. Change the engine oil after the first month or 20 hours and every six months or 100
hours thereafter. Replace the oil filter every 200 hours. Use SAE 10W-30 oil for general
all- temperature use. (figure # 7 and figure # 8)
6. Clean the air cleaner cover, filter elements and base every three months or 50 hours.
Replace the paper filter element every twelve months or 300 hours or if damaged or
excessively dirty.
7. Change the oil in the pressure pump after the first 50 hours and every 500 hours
thereafter. Use single-weight lubricating oil (SAE 30 weight non-detergent)
8. Change the spring for the gun trigger every 12 months or less if required. (figure # 32)
Page -
10
CaviBlaster 1228-G Operations Manual
For More information please email [email protected] or all 1-(352)275-5319