EN-7
Operation
Start operation
1. Cleaning the compartment
Before power on, clean inside of the appliance and check the drainage pipe in good
connection.
(
For details, please refer to the “Maintenance and cleaning”
)
2. Placement
Before powering on in the first time, keep it static at least 30 minutes.
3. Power on
The appliance start operation and it will cool down inside after 1 hour, otherwise you
should check the power connection.
Control panel
All keys would be invalid if in lock mode. Please unlock first.
ON/OFF
1. Keep pressing the key 3 seconds, power down, goes to stand-by mode.
2.Keep pressing the key again 3 seconds to return back to normal working.
Light
Press the key, turn on or turn off the LED lights inside. In stand-by mode, the key is
invalid.
UP
Press the key once, LED Display in regular flash showing current set temperature.
Continue pressing to adjust set temperature, one press increases 1
℃
. Regular flash
quit after 5 seconds detecting no press and new set temperature save. LED display
return to show actual temperature inside.
Down
Press the key once, LED Display in regular flash showing current set temperature.
Continue pressing to adjust set temperature, one press reduces 1
℃
. Regular flash quit
after 5 seconds detecting no press and new set temperature save. LED display return
to show actual temperature inside.