18
SCU32
User Manual
9M02-8679-A001-EN
Version 2.0
6.2
Input Terminals
The controller features a total number of 32 + 4 inputs for digital commands. The inputs have galvanic isolation by
means of optocouplers, which switch the electronic circuits. The optocouplers are rated for nominal voltages of
12/24 VDC.
6.2.1 Optocoupler Terminals (command functions) X2 through X5
The 32 optocoupler inputs are grouped together, with each group of eight optocouplers having a common
potential.
Terminal
Connection
Input
Description
X2
1
Optocoupler 1
DI 41
2
Optocoupler 2
DI 42
3
Optocoupler 3
DI 43
4
Optocoupler 4
DI 44
5
Optocoupler 5
DI 45
6
Optocoupler 6
DI 46
7
Optocoupler 7
DI 47
8
Optocoupler 8
DI 48
9
Common Potential Optocoupler 1 - 8
Terminal
Connection
Input
Description
X3
1
Optocoupler 9
DI 49
2
Optocoupler 10
DI 50
3
Optocoupler 11
DI 51
4
Optocoupler 12
DI 52
5
Optocoupler 13
DI 53
6
Optocoupler 14
DI 54
7
Optocoupler 15
DI 55
8
Optocoupler 16
DI 56
9
Common Potential Optocoupler 9 - 16
Terminal
Connection
Input
Description
X4
1
Optocoupler 17
DI 1
2
Optocoupler 18
DI 2
3
Optocoupler 19
DI 3
4
Optocoupler 20
DI 4
5
Optocoupler 21
DI 5
6
Optocoupler 22
DI 6
7
Optocoupler 23
DI 7
8
Optocoupler 24
DI 8
9
Common Potential Optocoupler 17 - 24