CattronControl™ LRC-S1
User Manual
16
9M02-9124-A001-EN
Version 2.0
4.5.2 Charging the Battery Pack
, charge the battery pack as follows:
1. Connect the jack plug from the Battery Charging Unit into the battery as shown in
Figure 8: LRC-S Rechargeable Battery and Charging Port
WARNING
LRC-S BATTERY CHARGING UNITS ARE DESIGNED ONLY FOR USE WITH CATTRON NICKEL
METAL HYDRIDE (NI-MH) BATTERY PACKS. OTHER BATTERY PACKS MAY EXPLODE WHEN
CHARGED WITH THIS DEVICE.
FAILURE TO COMPLY WITH THE ABOVE WARNING MAY RESULT IN SERIOUS INJURY OR
DEATH TO PERSONNEL AND DAMAGE TO EQUIPMENT.
2. Plug in the battery pack and observe that the red ‘Charge’ LED (2,
) illuminates to indicate the
charging mode. After approximately 5 seconds, a one minute battery test mode starts and is indicated by
the blinking green ‘Ready’ LED (3,
). If the green ‘Ready’ LED illuminates immediately after
connecting the battery and the red ‘Charge’ LED blinks from time to time after 20 seconds, the battery
pack is defective and can no longer be charged. If necessary, replace the battery pack with a new one.
Note:
Charging the battery pack can take up to three hours.
3. When the battery pack is fully charged, the red ‘Charge’ LED extinguishes and the green ‘Ready’ LED
illuminates.
4. The device switches to pulse trickle charge automatically and after about two minutes the green ‘Ready’
LED starts blinking. The battery may be used immediately or left until required.
!