background image

INSTRUCTION FOR THE INSTALLER  

 

 

 

 

 

        

GB

Before connecting and operating the unit for the first time read this manual carefully and follow its 

instructions. 

Installation ,servicing, starting of  the appliance and electrical connections must be done by 

qualified  personnel according to the legal requirements. 

INSTALLATION 

Positioning: the appliance shall be installed in well ventilated space and it can be positioned next to 

the walls with a good heat resistance; if not possible please observe a distance from wall of at least 

10 cm. all around the unit. 

Remove the protection foil completely from the entire unit, before connecting and operating the 

unit. 

TECHNICAL DATA

The data plate is on the back of the fryer and lists all the data deeded for connecting up to the 

mains.  

ELECTRICAL CONNECTION 

The rated voltage is 230V. Kw.3.4  for model FC4/M  and V.400/2+N  Kw.5.2 for model FC4/T, but 

check that voltage provided corresponds to oven requirements. 

If you want a direct connection to an electrical line it is necessary to have  an onnipolar switch with 

a contact opening of at least 3 mm., according to the load and to legal requirements.  

The yellow/green earth wire must not be cut off. 

The supply wire must not come into contact  with places exceeding by more than 50°C . 

Before carrying out  the electrical connection, make sure that: 

1) the fuses and the system are suitable for the power requirements of the appliance (see data 

label). 

2) The electric system has a right plate complying with the regulations in force. 

3) It must be easy to access to the plug or the omnipolar switch when the appliance is installed. 

Before using the oven ,we suggest to heat the oven to the max. temperature for about 30 

minutes so as to eliminate any residual factory grease that might impart unpleasant smells 

to the meals being cooked. 

Our company declines any liability in case the anti-accident regulation will not be observed. 

CONNECTION TO WATER SUPPLY  

To use humidifier you must connect valve located on the back of the oven to water supply with a 

3/4 G fitting. 

MANTEINANCE

As a safety measure, before you start using the oven, be sure to disconnect it from the electric 

system. 

No special maintenance is required: you only  need to check the condition of the electric wires, 

control panel as well as the heating elements. 