EN
23
Fit the back draft damper to the pipe
using the 12mm plastic self-tapping
screws (4) provided.
Seal around the power cord slot with
sealant to prevent any possible leakage.
Attach the duct connection adapter to the
end of the pipe with aluminium tape.
CONNECT EXTERNAL BLOWER
Connect the PRO SILENCE to the rangehood using the flexible 200mm diameter 6m ducting
provided.
Ensure the ducting installation is:
- Taut, remove excess ducting by trimming to the required length.
- Has at least 2 bends with recommended radius (at least two times the duct diameter)
- Is not crushed or kinked in any location.
External Blower
Roof
Ducting
Ceiling
Power cable
Hood