4
Please note
The ceramic hob must be installed by qualified personnel
or technicians
in accoradance with current regulations
. Please
never conduct the
installation
by yourself.
The ceramic hob
should
not be mounted
above
cooling equipment,
dishwashers and rotary dryers.
Please ensure there is adequate ventillation underneath the ceramic hob
to enhance its reliability
A steam cleaner is not to be used.
4.
1.
2.
3.
If the cable is damaged or to be replaced, the operation must be
carried out the by
a qualified electrician
with dedicated tools to avoid
any accidents.If the appliance is being connected directly to the
mains an omnipolar circuit-breaker must be installed with a
minimum opening of 3mm between contacts. The installer must
ensure that the correct electrical connection has been made and
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorised
technicians only.
4
Figure (3)
Power line connection
that it complies with
wiring diagram
.
The installer must ensure that the correct electrical connection has
been made and that it complies with wiring diagram above.
The socket shall be connected according to the relevant standard
blue
green-yellow
N2
N1
L2
L1
grey
brown
black
220-240V
220-240V
blue
green-yellow
N
L
grey
brown
black
220-240V
PE
PE
conne
c
t to the main power supply
conne
c
t to the main power supply
220-240V 2+2N~
220-240V 2+2N~
or connected to a single-pole cut-out. 30
amp
minimum supply.
The method of connection is shown in Figure (3):