All installation work must be carried out by a
competent person or qualified electrician.
Before connecting the mains supply ensure that
the mains voltage corresponds to the voltage on
the rating plate inside the cooker hood.
Warning:
THIS APPLIANCE MUST NOT
BE EARTHED
.
Mains Supply could be connected to the Mains Voltage by Direct
Connection
OFF
N(bleu)
L(brun)
N(bleu)
L(brun)
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3AMP FUSE
fUSE oN
EUR
UK
Direct Connection
If the appliance is being connected directly to the mains an
omnipolar circuit-breaker must be installed with a minimum
opening of 3mm between contacts.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
The installer must ensure that the correct electrical connection has
been made and that it complies with wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by authorized
technicians only.