![CASTLE TSM-21 Diagnostic Manual Download Page 13](http://html1.mh-extra.com/html/castle/tsm-21/tsm-21_diagnostic-manual_2572987013.webp)
Castle Inc
TSM-21 Diagnostic Manual v2
Page 13 of 63
4.3 Drill Operation
Page Procedure
Drill
DOES NOT come out, Machine Routs, Clamp DOES NOT release:
□
Check Drill Solenoid for function or blockage……………………..
40-41
21.51
□
Unclog Drill Solenoid…………………………………………………
38-39
21.50
Drill
comes out and stays out as soon as air is attached…with Machine power OFF:
Machine DOES NOT finish cycle when carriage is pushed forward by hand:
□
Check Drill Motor is On………………………………………………
33-34
21.40
□
Check Drill Stop Switch for function or adjustment……………….
37-38
21.43
Drill
comes out and stops, Router cuts pocket and Clamp DOES NOT release:
Machine DOES finish cycle when carriage is pushed forward by hand:
□
Adjust Air pressure, may be too low………………………………..
51-52
21.90
□
Check Drill Solenoid for function or blockage ……………………..
40-41
21.51
□
Unclog Drill Solenoid…………………………………………………
28-39
21.50
□
Check Router SQE Valve……………………………………………
(or Solenoid exhaust port ) for leakage
43-44
21.61
□
Check Drill SQE Valve……………………………………………….
(or Solenoid exhaust port ) for leakage
43-44
21.61
Drill
bit not completing pilot hole into Pocket:
□
Adjust air pressure, Machine cycling too slowly…………………..
51-52
21.90
□
Bit mounted too deep into collet…………………………………….
34-35
21.41
Drill
bit separating from the shank:
□
Adjust air pressure, Machine cycling too slowly…………………..
51-52
21.90
□
Bit mounted too deep into collet…………………………………….
34-35
21.41